Table 1-7. LCD Status Messages (continued)
Line 1
Line 2
Message
Message
E161C
PS # Input
Lost
E1620
PS # Input
Range
E1624
PS
Redundancy
E1625
PS AC
Current
E1710
I/O Channel
Chk
E1711
PCI PERR B##
D## F##
PCI PERR
Slot #
26
About Your System
Causes
Power source for specified
power supply is
unavailable, or out of
acceptable range.
Power source for specified
power supply is
unavailable, or out of
acceptable range.
Power supply redundancy
has been lost. If the
remaining power supply
fails the system will shut
down.
Power source is out of
acceptable range.
The system BIOS has
reported an I/O channel
check error.
The system BIOS has
reported a PCI parity
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
The system BIOS has
reported a PCI parity
error on a component
that resides in PCI slot #.
Corrective Actions
Check the AC power
source for the specified
power supply. If problem
persists, see
"Troubleshooting Power
Supplies" on page 156.
Check the AC power
source for the specified
power supply. If problem
persists, see
"Troubleshooting Power
Supplies" on page 156.
See "Troubleshooting
Power Supplies" on
page 156.
Check the AC power
source.
See "Getting Help" on
page 181.
Remove and reseat the
specified PCI expansion
card. If the problem
persists, see
"Troubleshooting
Expansion Cards" on
page 166. If
troubleshooting does not
resolve the problem, see
"Getting Help" on
page 181.

Advertisement