Table 1-6. System Messages (continued)
Message
Plug & Play
Configuration Error
Read fault
Requested sector
not found
Remote
configuration
update attempt
failed
ROM bad checksum =
address
SATA PORT n drive
not found
Sector not found
Seek error
Seek operation
failed
36
About Your System
Causes
Error encountered in
initializing PCIe device;
faulty system board.
The operating system
cannot read from the hard
drive or USB device, the
system could not find a
particular sector on the
disk, or the requested
sector is defective.
System unable to process
Remote Configuration
request.
Expansion card
improperly installed or
faulty.
SATA port x was turned
on in setup, but a drive
was not found.
Faulty hard drive, USB
device, or USB medium.
Corrective Actions
Install the NVRAM_CLR
jumper and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists, see
"Troubleshooting Expansion
Cards" on page 159.
Replace the USB medium or
device. Ensure that the USB
or hard drive cables are
properly connected. See
"Troubleshooting a USB
Device" on page 138, or
"Troubleshooting a Hard
Drive" on page 153 for the
appropriate drive(s) installed
in your system.
Retry Remote Configuration.
Reseat the expansion card(s)
and expansion card cables. If
the problem persists, see
"Troubleshooting Expansion
Cards" on page 159.
See "Troubleshooting a Hard
Drive" on page 153 for the
appropriate drive(s) installed
in your system.
See "Troubleshooting a USB
Device" on page 138 or
"Troubleshooting a Hard
Drive" on page 153 for the
appropriate drive(s) installed
in your system.