Table 1-5. LCD Status Messages (continued)
Code
Text
E201C SMI Init
E201D Shutdown Test BIOS shutdown test failure. See "Getting Help" on
E201E POST Mem Test BIOS POST memory test
E201F DRAC Config
E2020 CPU Config
E2021 Memory
Population
E2022 POST Fail
E2110 MBE DIMM # &
#
Causes
System management
interrupt (SMI)
initialization failure.
failure.
Remote Access Controller
(RAC) configuration failure.
CPU configuration failure.
Incorrect memory
configuration. Memory
population order incorrect.
General failure after video.
One of the DIMMs in the
set implicated by "# & #"
has had a memory multi-bit
error (MBE).
Corrective Actions
See "Getting Help" on
page 175.
page 175.
See "Troubleshooting
System Memory" on
page 146. If the problem
persists, see "Getting
Help" on page 175.
Check screen for specific
error messages. Ensure
that RAC cables and
connectors are properly
seated. If problem
persists, see your RAC
documentation.
Check screen for specific
error messages.
Check screen for specific
error messages (see
"Troubleshooting System
Memory" on page 146).
Check screen for specific
error messages.
See "Troubleshooting
System Memory" on
page 146.
About Your System