Table 1-5. LCD Status Messages (continued)
Code
Text
E1624 PS Redundancy The power supply subsystem
E1710 I/O Channel
Chk
E1711 PCI PERR B##
D## F##
PCI PERR Slot
#
E1712 PCI SERR B##
D## F##
PCI SERR Slot
#
E1714 Unknown Err
24
About Your System
Causes
is no longer redundant. If
the last supply fails, the
system will go down.
The system BIOS has
reported an I/O channel
check.
The system BIOS has
reported a PCI parity error
on a component that resides
in PCI configuration space
at bus ##, device ##,
function ##.
The system BIOS has
reported a PCI parity error
on a component that resides
in the specified PCIe slot.
The system BIOS has
reported a PCI system error
on a component that resides
in PCI configuration space
at bus ##, device ##,
function ##.
The system BIOS has
reported a PCI system error
on a component that resides
in the specified slot.
The system BIOS has
determined that there has
been an error in the system,
but is unable to determine
its origin.
Corrective Actions
See "Troubleshooting
Redundant Power
Supplies" on page 143.
See "Getting Help" on
page 175.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 159. If
troubleshooting does not
resolve the problem, see
"Getting Help" on
page 175.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 159. If
troubleshooting does not
resolve the problem, see
"Getting Help" on
page 175.
See "Getting Help" on
page 175.