Table 1-6. System Messages (continued)
Message
Memory address line
failure at address ,
read value
expecting value
Memory double word
logic failure at
address , read value
expecting value
Memory odd/even
logic failure at
address, read value
expecting value
Memory write/read
failure at address ,
read value
expecting value
Memory tests
terminated by
keystroke
No boot device
available
34
About Your System
Causes
Faulty or improperly
installed memory
modules.
POST memory test
terminated by pressing
the spacebar.
Faulty or missing optical
drive subsystem, hard
drive, or hard-drive
subsystem, or no bootable
USB key installed.
Corrective Actions
See "Troubleshooting System
Memory" on page 146.
Information only.
Use a bootable USB key, CD,
or hard drive. If the problem
persists, see
"Troubleshooting an Internal
USB Memory Key" on
page 148 and
"Troubleshooting a Hard
Drive" on page 153. See
"Using the System Setup
Program" on page 41 for
information on setting the
order of boot devices.