6. SWICH SETTING OF THE CONVERTER
Explains each switch of the NCV-20NDN.
6-1. DeviceNet Setting
6-1-1. Node address and baud rate setting
Set the node address and baud rate by the DeviceNet setting switch on the panel.
DeviceNet setting switch
Node address
Baud rate
● Node address (NA)
Setting range: 0-63
Setting method: 1-32 (2
Setting example: Turn ON "1 (SW6)" "4 (SW4)" when setting the node address 5.
Panel display
Numeric value
significance
Note
The node address should not duplicate with the master or slave unit.
● Baud rate (DR)
The setting range is the following three.
Baud rate
Setting is prohibited
-2
) is set by the binary.
0
5
32
16
2
2
5
4
Panel display
1
125 kbps
OFF
250 kbps
OFF
500 kbps
ON
ON
All setting is OFF when shipping from the factory.
NA
8
4
2
1
2
2
2
2
3
2
1
0
DR
0
OFF
ON
OFF
ON
18