17.2. CE Marking
The CE mark certifies that the products meet the essential requirements of the applicable
regulations in line with the declaration of conformity. The manufacturer can be consulted for a
declaration of conformity.
Product Information Sheet (ErP)
The product data presented below complies with the requirements of EU regulations 811/2013 and
813/2013 to supplement directives 92/42/EU and 92/42/EEC.
CE PIN Number: 0085CS0133
Product Data
Condensing boiler
Low-temperature boiler(*b)
B1 boiler
Cogeneration Space Heater
Combination Heater
Useful Heat Output
Rated heat output (*e)
At rated heat output and high temperature
regime (*a)
At 30% of rated heat output and low
temperature regime
Auxiliary Electricity Consumption
At full load
At part load
In Standby mode
Space Heating Efficiency
Seasonal space heating energy efficiency
class
Seasonal space heating energy efficiency
At rated heat output and high temperature
regime (*c)
At 30% of rated heat output and low
temperature regime (*d)
For Combination Heaters (*f)
Temperature application (*f)
Declared load profile (*f)
Water heating energy efficiency class (*f)
Water heating energy efficiency (*f)
Daily fuel consumption (*f)
Annual fuel consumption (*f)
Other Items
Standby Heat Loss
Ignition Burner Power Consumption
Annual Energy Consumption
Daily Electricity Consumption
Annual Electricity Consumption
Sound Power Level
Emission of Nitrogen Oxide
Indication about ability working only during
off-peak hours
Manufacturer
Address of the Manufacturer
(*a) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at
heater outlet.
(*b) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other
heaters 50 °C return temperature (at heater inlet).
(*c) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at
heater outlet.
(*d) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other
heaters 50 °C return temperature (at heater inlet).
(*e) For heat pump heaters and combined heaters, the rated heat output Prated is the same as the standard
load in heating mode Pdesignh. The rated heat output of a Psup auxiliary heating device is the same as the
auxiliary heating power sup(Tj).
(*f) valid for HM models.
CALORA PREMIX CALORA PREMIX CALORA PREMIX CALORA PREMIX CALORA PREMIX CALORA PREMIX
Symbol
Unit
14 HM-HCH-HST 20 HM-HCH-HST 24 HM-HCH-HST 28 HM-HCH-HST 30 HM-HCH-HST 35 HM-HCH-HST
Yes
No
No
No
Prated
kW
14
P4
kW
14,1
P1
kW
6,7
elmax
kW
0,02
elmin
kW
0,012
PSB
kW
0,004
A
ηs
%
91,2
η4
%
87,9
η1
%
97
Medium
XL
A
ηwh
%
90,7
Qfuel
kWh
23,072
AFC
Gj
18
Pstby
kW
0,065
Pign
kW
0
QHE
kWh
12267
Qelec
kWh
0,427
AEC average
kWh
44
L
db(A)
52
wA
NOx
mg/kWh
31,18
No
Emas Makina Sanayi A.Ş.
Mustafa Kemal Bulvarı Organize Sanayi Bölgesi 3.Kısım No: 13 45030 MANİSA
Table 6
32
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
Yes (for HM models) / No (for HCH and HST models)
20
24
28
20,2
24,5
28
6,7
8,1
9,2
0,029
0,04
0,051
0,012
0,012
0,012
0,004
0,005
0,004
A
A
A
91,5
92,2
92,4
87,9
87,9
87,9
97
97,2
97,4
Medium
Medium
Medium
XL
XL
XL
A
A
A
90,7
83,6
83,9
23,072
22,8
22,8
18
18
18
0,065
0,065
0,065
0
0
0
17574
21315
24360
0,427
0,2
0,22
44
44
44
52
52
52
30,89
53
21,29
No
No
No
Yes
Yes
No
No
No
No
No
No
30
35
30
35
9,9
11,5
0,056
0,066
0,013
0,013
0,004
0,004
A
A
92
92,9
87,9
87,9
97
97,9
Medium
Medium
XL
XL
A
A
82,8
82,8
23,021
23,021
18
18
0,065
0,065
0
0
26100
30450
0,24
0,24
44
44
52
52
25,91
25,91
No
No