Download Print this page

Technical Specifications Table - E.C.A. CALORA PREMIX Installation And User's Operating Instructions

Condensing boiler

Advertisement

17. ERP GUIDE

17.1. Technical Specifications Table

Product Type
Gas Category
Flue Type
Gas Input Pressure (Natural Gas-G20)
Gas Input Pressure (LPG-G31)
Min. Heating Power - (60°C min)
Max. Heating Power - 80/60°C
Min. Heating Power - (30°C min)
Max. Heating Power - 50/30°C
Min. Heat Input (min)
Max. Heat Input (max)
Natural Gas (@Min-Max Capacity)
Propane (@Min-Max Capacity)
NO
Class
X
Min. Water Pressure
Max. Water Pressure
Operation Range (Radiator Heating)
Operation Range (Underfloor Heating)
Max. Limit Temperature
Min. Flow Rate for Operation (*f)
Min. Flow Rate for Closing (*f)
Max. Flow Rate (*f)
Min. Water Pressure (*f)
Max. Water Pressure (*f)
Operation Range (*f)
Max. Limit Temperature (*f)
Electrical Supply
Electrical Consumption (Max-HE Pump)
Protection Class
Expansion Vessel
Weight (Net)
Dimensions (HxWxD)
C13 – 60/100 Max.
C13 – 80/125 Max.
C33 – 60/100 Max.
C33 – 80/125 Max.
C43 – 60/100 Max.
C53 – 60/100 Max.
C83 – 80/80 Max.
C83 – 80/80 Min.
B23 – 80 Max.
B33- 60/100 Max.
C0
ratio (@max-G20)
2
C0
ratio (@min-G20)
2
C0
ratio (@max-G31)
2
C0
ratio (@min-G31)
2
Operation Range (*g)
Max. Limit Temperature (*g)
(*f) Applies to HM models.
(*g) Applies to HST models.
CALORA
CALORA
Unit
PREMIX 14
PREMIX 20
HM-HCH-HST
HM-HCH-HST
I2H, I3P, I2Esi, I2E(S), II2L3P, II2H3P, II2ELL3P, II2Esi3P
C13(X), C33(X), C43(X), C53(X), C63(X), C83(X), B23, B33
mbar
mbar
Capacity-Efficiency
kW
5,6
5,6
kW
14,1
20,2
kW
6,7
6,7
kW
15
22,2
kW
6,2
6,2
kW
14,5
20,7
Gas Consumption
3
/h
0,65-1,53
0,65-2,2
m
kg/h
0,51-1,2
0,51-1,7
6
6
Central Heating
bar
0,4
0,4
bar
3
3
o
30-80
30-80
C
o
C
30-45
30-45
o
> 90
> 90
C
Domestic Hot Water (*f)
L/dk
2 (±%10)
2 (±%10)
L/dk
1,5 (±%10)
1,5 (±%10)
10 ±%15
10 ±%15
L/dk
(ΔT = 34,7°C)
(ΔT = 34,7°C)
bar
0,4
0,4
bar
10
10
o
C
30-65
30-65
o
≥ 71
≥ 71
C
General
V AC-Hz
Watt
65
80
lt
kg
28,5
28,5
mm
Flue Lengths
m
10
10
m
20
20
m
10
10
m
20
20
m
10
10
m
10
10
m
28
28
m
3
3
m
28
28
m
10
10
Emission Values
%
9,2 ± 0,2
9,2 ± 0,2
%
8,7 ± 0,2
8,7 ± 0,2
%
10,4± 0,2
10,4± 0,2
%
9,6 ± 0,2
9,6 ± 0,2
Boiler Circuit (*g)
o
30-65
30-65
C
o
C
≤ 85
≤ 85
Table 5
31
CALORA
CALORA
PREMIX 24
PREMIX 28
HM-HCH-HST
HM-HCH-HST
HM-HCH-HST
20
37/50
5,6
6,4
24,5
28
6,7
7,7
26
29,6
6,2
7,2
25,2
28,7
0,65-2,65
0,75-3,02
0,51-1,98
0,59-2,26
6
6
0,4
0,4
3
3
30-80
30-80
30-45
30-45
> 90
> 90
2 (±%10)
2 (±%10)
1,5 (±%10)
1,5 (±%10)
10 ±%15
12 ±%15
(ΔT = 34,7°C)
(ΔT = 33,5°C)
(ΔT = 35,8°C)
0,4
0,4
10
10
30-65
30-65
≥ 71
≥ 71
230 VAC-50 Hz
85
110
IPX4D
8
28,5
30
678*410*288
10
10
20
20
10
10
20
20
10
10
10
10
28
28
3
3
28
28
10
10
9,3 ± 0,2
9,5 ± 0,2
8,7 ± 0,2
8,9 ± 0,2
10,4± 0,2
10,6 ± 0,2
9,6 ± 0,2
9,9 ± 0,2
30-65
30-65
≤ 85
≤ 85
CALORA
CALORA
PREMIX 30
PREMIX 35
HM-HCH-HST
6,9
8
30
35
8,3
9,6
31,7
37
7,7
9
30,8
35,9
0,81-3,25
0,94-3,79
0,63-2,46
0,74-2,87
6
6
0,4
0,4
3
3
30-80
30-80
30-45
30-45
> 90
> 90
2 (±%10)
2 (±%10)
1,5 (±%10)
1,5 (±%10)
12 ±%15
14 ±%15
(ΔT = 35,8°C)
0,4
0,4
10
10
30-65
30-65
≥ 71
≥ 71
130
165
30
32
10
10
20
20
10
10
20
20
10
10
10
10
28
28
3
3
28
28
10
10
9,5 ± 0,2
9,5 ± 0,2
8,9 ± 0,2
8,9 ± 0,2
10,6 ± 0,2
10,6 ± 0,2
9,9 ± 0,2
9,9 ± 0,2
30-65
30-65
≤ 85
≤ 85

Advertisement

loading
Need help?

Need help?

Do you have a question about the CALORA PREMIX and is the answer not in the manual?