E.C.A. GELIOS PLUS 11/13/16/20/24/28 kW hermetic combi boilers have been designed for efficient, safe and comfortable central heating and domestic hot water requirement. Detailed explanations regarding technical features of the device, selection of the point of assembly, making the connections (water, gas, flue and electric), maintenance information, determination of possible malfunctions and troubleshooting have been provided in the guide.
Page 4
Call your qualified person as soon as possible. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision...
Page 5
E.C.A. GELIOS PLUS 11/13/16/20/24/28 kW hermetic combi boilers is far central heating and domestic hot water usage. It enables saving of place by its design that provides ease of service and maintenance and by its size of 720x400x330. it has a delicate appearance with its round lines and design. lts control panel has been designed in an ergonomic structure.
Page 7
12- GAS VALVE 1- ROOM THERMOSTAT (Opt.) 13- SUPPLY CABLE 2- GAS VALVE MODULATOR 14- 3 WAY VALVE 3- CH TEMPERATURE SENSOR 15- POTENTIOMETER DHW TEMP. 4- WATER PRESSURE SENSOR 16- POTENTIOMETER CH. TEMP. 5- LIMIT THERMOSTAT 17- ON / OFF / RESET / SUMMER / WINTER MODE 6- AIR PRESSURE SWITCH 18- FUSE 7- DHW TEMPERATURE SENSOR...
Page 8
PACKAGING CAUTION: The warnings of the cardboard packaging should be considered during the transportation and storage of device. - The device is delivered within a cardboard box as supported with bottom and top styrofoams with a size of 865 x 470 x 405 (HxWxD) (Figure 2). Figure 2 +The parts required for the assembly of the device (wall hanger bracket, 5 gaskets for water and gas connections, 3 dowels and lock screws) has been placed on the top styrofoam.
Page 9
ASSEMBLY Determination of the Location where the Device will be Assembled - It should be conformed to the rules determined by TSE and authorized gas institutions for the locations where the device may be assembled. - If the device had been assembled inside a cabinet, the distances required for maintenance and repair should be at least as in Figure 3.
Page 10
Vehicle area Min distancetothe roof Human area...
Page 11
Figure 4a POSITION DISTANCE (cm) POSITION DISTANCE (cm) A-Below a windows G- Next to vertical or horizontal pipe H- Below the distance grille from the outside B- Below an air vent of the building C- Below rain channel I- Distance from the inner corner of the buildina D- Under the balcony L- From the ground or from the fioor...
Page 12
• In C type devices, the horizontal outlets should be assembled by a 1-2% downward inclination at the outside for rain water etc. not to enter inside the device (Figure 5a). • The distance of waste gas outlet with the opposite building should be at least 3 m. i n the direction of discharge of waste gas (Figure 5b).
Page 13
In case of assembly of the device at attics or at rooms under the roof/terrace, • The flue outlet should be at least 40 cm higher than the roof (Figure Sd and Se). • The ceilin g should be resistan t to high temperature. "Hermetic flue group", en ablin g the fresh combustion air supply and waste gas exit of the device, should be isolated with material resistant to high temperature at the roof space.
Page 14
for 28 kW 1. Horizontal flue connection (ø 60 /100 mm ) up to max. 4 meters 1. 5 meters 2. Vertical flue connection (ø 60 /100 mm ) up to max. 4 meters 2. 6 meters 3. 12 meters 3.
Page 15
Connection of Horizontal (060/lOOmm) Hermetic Flue Set to the Combi Boiler As your combi boiler is hermetic model, it takes the air used from the external environment, and discharges the waste gases arising as the result of combustion from the same flue group. The use and assembly of flue is very important for the extremely harmful waste gases not to be spread i n the environment, thus the warnings should be considered while making the flue connections.
Page 16
Figure 9a Figure 9b Figure 9c Figure 9e Issues to be Considered in Flue Connection Extensions In case the hermetic flue set -provided by the packaging of the product- is of insufficient length, additional hermetic flue accessories should be ordered from an authorized E.C.A. vendor as per requirement, and other hermetic flue accessories should not be used.
Page 17
GELIOS PLUS 24 , 20 kW GELIOS PLUS 16 , 13 , 11 kW GELIOS PLUS 4 < 28 kW Restrict or Fan...
Page 19
4 < GELIOS PLUS 24 , 20 kW 4 < GELIOS PLUS 16, 13, 11 kW...
Page 24
First the electric connection of the combi boiler is made. All the radiator valves are opened. The valves of central heating outlet - return lines of the combi boiler should be open. Check it. After this operation, start the filling operation by slowly opening the filling valve.
Page 26
Bar Position Turn the position selection button to the right, to the bar symbol. In this position water pressure will be shown on screen. If the button is left at bar position, boiler will run in summer mode so, central heating system will not get hot water.