E.C.A. FELIS Series Installation And User Manual

E.C.A. FELIS Series Installation And User Manual

Wall hung

Advertisement

FELIS
WALL HUNG CONDENSING BOILER
FELIS FL 50/65/100/125/150 HM
INSTALLATION AND
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FELIS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for E.C.A. FELIS Series

  • Page 1 FELIS WALL HUNG CONDENSING BOILER FELIS FL 50/65/100/125/150 HM INSTALLATION AND USER MANUAL...
  • Page 3: Table Of Contents

    • • CONTENTS • INTRODUCTION • WARRANTY AND SERVICE • SYMBOLS SAFETY RULES AND WARNINGS Safety Rules Fittings Cascading Applications Installation Commissioning • Operation and Maintenance PRODUCT Product Features Product Notation and Technical Dimensions Detailed Drawings and List of Components Technical Specification Table •...
  • Page 4: Introduction

    INTRODUCTION First of all, we would like to thank you for choosing an E.C.A. boiler. E.C.A. Felis condensing boilers are designed to accomodate the central heating needs in a safe and comfortable way. Felis boilers must be installed to a central heating plumbing and sanitary water system selected suitably for the boiler’s capacity and performance.
  • Page 5: Safety Rules And Warnings

    SAFETY RULES AND WARNINGS SAFETY RULES If there is a natural gas smell; - Shut off the gas valve of the appliance and all of your gas burning appliance - Shut off and put out your oven, stove, cooker etc. - Do not light matches, lighters etc, put out your cigarettes.
  • Page 6: Installation

    All data regarding the cascade installation can be seen from the control panel of the master appliance, therefore slave appliances don’t need to have a separate control panel. LEDs on the appliances indicate error states and burning statuses. If a single appliance falls into an error state, error code and the appliance address can be seen from the control panel of the master appliance and the error can be reset from the button on the aforementioned slave appliance.
  • Page 7: Product Features

    CAUTION: Any person who is not capable in physical, sensory or emotional aspect (including children) shall not operate the appli- ance without observation. CAUTION: This appliance is not suitable for use by the people who is not capable in physical, sensory or emotional aspects without observation and information of the people responsible for the appliance.
  • Page 8: Product Notation And Technical Dimensions

    Product Notation Description Notation Felis 50, 65, 100, 125, 150 HM NG E.C.A. Felis Wall Hung Condensing Boiler Technical Dimensions Figure 1. Technical Dimensions Dimensions Ø F Ø G Ø H Ø I Felis FL 50 HM DG 501 mm 835 mm 525 mm 145 mm 304 mm 80/125 mm 1 1/4"...
  • Page 9: Detailed Drawings And List Of Components

    Detailed Drawings and List of Components Felis 50 Figure 2a. Felis 50 Detailed Drawings No Description No Description 1 GAS VALVE 11 PRESSURE SENSOR 2 SAFETY LIMIT THERMOSTAT 12 SIPHON COVER 3 NTC TEMP. SENSOR (OUTLET) 13 CONDENSATION HOSE 4 IGNITION TRANSFORMER 14 BOILER OUTLET PIPE (HOT) 5 HEAT EXCHANGER 15 BOILER INLET PIPE (COLD)
  • Page 10 Felis 65 Figure 2b. Felis 65 Detailed Drawings...
  • Page 11 Felis 100 / 125 / 150 Figure 2c. Felis 100 / 125 / 150 Detailed Drawings...
  • Page 12: Technical Specification Table

    Technical Specifications Table Product Type Unit FELIS FL 50 HM NG FELIS FL 65 HM NG FELIS FL 100 HM NG FELIS FL 125 HM NG FELIS FL 150 HM NG General Gas Category I2H, I2E Flue Types C13(x), C33(x), C43(x), C63(x), C93(x),B23P Hermetic Type Fully Hermetic Gas Inlet Pressure (G20)
  • Page 13 Electrical Board Circuit Diagram Figure 3. Electronic Board Circuit Diagram...
  • Page 14: Packaging

    Packaging CAUTION: Warnings on the packaging must be followed during transportation and storage. The appliance is delivered in a 1055 x 665 mm cardboard box with 4 pieces of edge styrofoams supporting the appliance. Figure 4. Product Packaging Concept Parts required for the installation of the product (Wall hanging bracket, 3 gaskets for water and gas connection, 5 wall plugs for screws) is provided in the package.
  • Page 15 Selecting the Suitable Place for Installation Gas and water connections are placed at the bottom of appliance, while flue gas outlet and air inlet are located on the top. Boiler is sold with the outlet pipes directed to the bottom side. Suitable places for installation are defined by the local regulations and the authorized gas companies.
  • Page 16 CONNECTIONS Water Connection Instructions Before the installation of your boiler, water circuit must be cleaned with suitable/approved chemi- cals. To not damage the metal, plastic and rubber parts of the pipings and fittings, use neutral based, non-acidic and non-alcalic cleaners. When using these chemicals, please follow the instructions. Any dirt, blockages, welding residuals, burr, flug etc.
  • Page 17 Flue Connections E.C.A. Felis boilers are designed to work with C-type flues to provide the air required for burning from out of boiler room. During flue connections, tightness gaskets should be mounted correctly to prevent flue gas leakage to the fresh air intake. Horizontal flue kit must be installed with a 3% slope towards the appliance to keep the condansate water flowing.
  • Page 18 +-{d +-{d Figure 7. Flue Types...
  • Page 19 Room Thermostat (Optional) A selection of compatible room thermostats can be used for heating control of the system. E.C.A. On-Off Room Thermostat AF18 Room Unit T6360 7006721436 7006901312 Figure 8a Figure 8b E.C.A. On-Off Room Thermostat AF17 Digital Room Unit Wireless: 7006907522 7006721435 Wired: 7006907519...
  • Page 20: Operating

    OPERATING First time operation of the appliance must be made by an authorized service. Before first time opera- tion, required parameter changes must be made by the service according to the components used in the heating application. Please inform the authorized service about the additional components (storage tank, 3-way valve, pool heating etc.) in your installation, so required INFORMATION parameter settings can be done.
  • Page 21 Slave appliances in a cascading application will have a user interface without the screen and keypads. LEDs on the slave appliances indicate error states and burning statuses. Possible errors can be detected on the screen of the master appliance and can be manually reset from the reset button on the slave appliances.
  • Page 22: Date/ Time Settings

    DATE / TIME SETTINGS Ensuring that the date and time setting of your appliance is right is essential for time programs and summer/winter changeovers to work correctly. When in the main screen press OK to enter the menu, and enter the “Time of day and date” submenu to change the date / time setting and summer/winter changeover dates.
  • Page 23: Working Modes

    WORKING MODES Selection of the Heating Mode Switching between four different heating modes is done by pressing the Heating Mode button on the upper right side of panel. Selected heating mode is indicated in the LED screen by a horizontal line under the corresponding heating mode symbol.
  • Page 24 P. No Description Comfort setpoint 1010 1310 Reduced setpoint 1012 1312 Frost protection setpoint 1014 1314 1020 1320 Heating curve slope 1026 1326 Heating curve adjustion Figure 15. Comfort Setpoint Adjustion Heating curve are used for creating a water temperature set point according to the current outside temperature conditions.
  • Page 25 Manual operation When manual operation is in effect, appliance works according to a user defined manual setpoint rather than the current heating mode or time programs. After activating manual operation mode, pressing “Return” button goes back to main screen. When maintenance/special operation symbol appears on the screen, user can press “Info”...
  • Page 26 DHW heating can be released in 3 different ways: - 24h/day When this setting is used, DHW heating is continuously released as long as it is On. The DHW setpoint is always the Nominal setpoint, unless the Legionella function has been activated. Setting Once/day or Several times/day has no impact.
  • Page 27 Legionella function When the Legionella function is activated, the DHW storage tank temperature is periodically raised to the Legionella funct setpoint. The Legionella funct setpoint can be maintained during the set dwelling time. Function is deactivated. Periodically The Legionella function is repeated according to the period (Legionella funct periodically 1641)).
  • Page 28 Stand-by and Holiday Function CAUTION: Do not cut the supply power even if the boiler is not in use. The boiler must be plugged in and supplied with electricity to activate frost protection mode. When the heating system will not be in use for a prolonged period of time, the boiler can be set to Frost Protection mode by pressing the heating mode selection button or can be set to holiday program to set the boiler to work according to holiday dates.
  • Page 29: Error/ Fault Codes

    ERROR / FAULT CODES There are several control mechanisms adapted in the boiler control to ensure a safe operation. Inconsistencies occured during these controls will be shown as error and fault codes on the LCD screen and will be indicated with a bell sign on the upper left. Some detailed information for the possible error / fault codes is provided in the following table.
  • Page 34: Maintenance

    MAINTENANCE Appliance must go under maintenance at the start of every heating season. Please refer to E.C.A. authorized services for maintenance. Outer surfaces of the appliance must be cleaned with a damp cloth without using any chemical substances. Usage of chemicals like detergents etc. could cause rust and scratches. ALL RIGHTS RESERVED.
  • Page 35 FELIS 50 kW CIRCUIT AND FLUE CONNECTIONS 145 mm 220 mm 65 mm 240 mm 330 mm 435 mm 105 mm 235 mm SIPHON CH RETURN 1 ¼" CH FLOW 1 ¼" ¾" FLUE Ø 80/125mm...
  • Page 36 FELIS 65 kW CIRCUIT AND FLUE CONNECTIONS 145 mm 220 mm 65 mm 240 mm 435 mm 445 mm 105 mm 260 mm SIPHON CH RETURN 1 ¼" CH FLOW1 ¼" ¾" FLUE Ø 80/125mm...
  • Page 37 FELIS 100 kW CIRCUIT AND FLUE CONNECTIONS 236 mm 145 mm 71 mm 93 mm 280 mm 405 mm 98 mm 130 mm SIPHON 185 mm CH RETURN 1 ¼" CH FLOW 1 ¼" 290 mm " FLUE Ø 100/150mm...
  • Page 38 FELIS 125 kW CIRCUIT AND FLUE CONNECTIONS 236 mm 145 mm 71 mm 93 mm 280 mm 405 mm 98 mm 130 mm SIPHON 185 mm CH RETURN 1 ¼" CH FLOW 1 ¼" 365 mm " FLUE Ø 100/150mm...
  • Page 39 FELIS 150 kW CIRCUIT AND FLUE CONNECTIONS 236 mm 145 mm 71 mm 93 mm 270 mm 98 mm 405 mm 210 mm SIPHON CH RETURN 1 ¼" CH FLOW 1 ¼" 437 mm " FLUE Ø 100/150mm...
  • Page 41 INFORMATION ABOUT REGULATIONS EU 811/2013 AND EU 813/2013 FELİS FL 50/65/100/125/150 HM Product Fiches and Package Label Calculations...
  • Page 42 Product fiche for combination boilers as required by EU regulations No 811/2013 Units Felis Condensing Boiler Supplier's name or trademark E.C.A. Felis FL 65 HM Felis FL 100 HM Felis FL 125 HM Felis FL 150 HM Supplier's model identifier Felis FL 50 HM Space Heating-Temperature application Medium...
  • Page 43 PACKAGE LABEL CALCULATIONS Package fiche for boilers indicating the space heating energy efficiency of the package Package Fiche-Boilers Seasonal space heating energy efficiency of boiler 'I' : The value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %. Class I = 1%, Class II = 2%, Class III = 1.5%, Temperature Control Class IV = 2%, Class V = 3%, Class VI = 4%,...
  • Page 44 Boiler and supplementary heat pump installed with low temperature heat emitters at 35°C? from fiche of heat pump + ( 50 x 'II' ) = Weighting of Boilers II, package without hot water storage (1)(2) II, package with hot water storage tank Psup / (Prated+Psup) tank 0.37...
  • Page 45: Ec Declaration Of Conformity

    EMAS MAKİNA SANAYİ A.Ş. AT UYGUNLUK BEYANI EC DECLARATION OF CONFORMITY Üretici/Manufacturer: EMAS MAKİNA SANAYİ A.Ş. Adress : Mustafa Kemal Bulvarı Organize Sanayi Bölgesi 3.Kısım No: 13, 45030 MANİSA-TURKEY Tel : +90 236 213 00 21 pbx Faks : +90 236 213 08 59 Onay Kuruluşu/Notified Body: 0085 - DVGW CERT GmbH, Josef-Wirmer Str.
  • Page 47 SELLER COMPANY Invoice Date and N o ................TIiie Delivery Date and Pio�.; ..............Address Date, Signature and Stamp .......... Phone - Fax.: Type Gas Fueled Boiler Serial N o Delivery Place and Date.: Brand E.C.A....Maximum Repair Period : 2 0 Work Days Model Warranty Period : 3 Years...
  • Page 48 PRODUCTION PRODUCTION EMAS MAKINA SANAYI A.S Organize Sanayi Bölgesi 3. Kısım Organize Sanayi Bölgesi 3. Kısım Mustafa Kemal Bulvarı No: 13 45030 MANISA Mustafa Kemal Bulvarı No: 13 45030 MANISA TURKEY Tel. : +90 236 213 00 21 Tel. : +90 236 213 00 21 Fax : +90 236 213 08 59 Fax : +90 236 213 08 59 email: emas@emas.com.tr www.emas.com.tr...