Roland XV-5050 Owner's Manual page 157

64 voices 2x expansion sound generator
Hide thumbs Also See for XV-5050:
Table of Contents

Advertisement

●OMNI OFF (Controller number 124)
Status
2nd byte
BnH
7CH
n = MIDI channel number: 0H - FH (ch.1 - 16)
* The same processing will be carried out as when All Notes Off is received.
●OMNI ON (Controller number 125)
Status
2nd byte
BnH
7DH
n = MIDI channel number: 0H - FH (ch.1 - 16)
* The same processing will be carried out as when All Notes Off is received. OMNI ON
will not be turned on.
●MONO (Controller number 126)
Status
2nd byte
BnH
7EH
n = MIDI channel number:
mm = mono number:
* The same processing will be carried out as when All Notes Off is received.
* In Performance mode, the Part Mono/Poly parameter (PERFORM/PART) will change.
●POLY (Controller number 127)
Status
2nd byte
BnH
7FH
n = MIDI channel number: 0H - FH (ch.1 - 16)
* The same processing will be carried out as when All Notes Off is received.
* In Performance mode, the Part Mono/Poly parameter (PERFORM/PART) will change.
■System Realtime Message
●Active Sensing
Status
FEH
* When Active Sensing is received, the unit will begin monitoring the intervals of all
further messages. While monitoring, if the interval between messages exceeds 420 ms,
the same processing will be carried out as when All Sounds Off, All Notes Off and Reset
All Controllers are received, and message interval monitoring will be halted.
■System Exclusive Message
Status
Data byte
F0H
iiH, ddH, ......,eeH
F0H:
System Exclusive Message status
ii = ID number:
This is the ID number (manufacturer ID) to indicate the manufacturer
whose Exclusive message. Roland's manufacturer ID is 41H.
ID numbers 7EH and 7FH are extensions of the MIDI standard;
Universal Non-realtime Messages (7EH) and Universal Realtime
Messages (7FH).
dd,...,ee = data:
00H - 7FH (0 - 127)
F7H:
EOX (End Of Exclusive)
Of the System Exclusive messages received by this device, the Universal Non-realtime
messages and the Universal Realtime messages and the Data Request (RQ1) messages and
the Data Set (DT1) messages will be set automatically.
●Universal Non-realtime System Exclusive Messages
❍Identity Request Message
Status
Data byte
F0H
7EH, dev, 06H, 01H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (Universal Non-realtime Message)
dev
Device ID (dev: 10H - 1FH, 7FH)
06H
Sub ID#1 (General Information)
01H
Sub ID#2 (Identity Request)
F7H
EOX (End Of Exclusive)
* When this message is received, Identity Reply message (p. 161) will be transmitted.
3rd byte
00H
3rd byte
00H
3rd byte
mmH
0H - FH (ch.1 - 16)
00H - 10H (0 - 16)
3rd byte
00H
Status
F7H
Status
F7H
MIDI Implementation
❍GM1 System On
Status
Data byte
F0H
7EH, 7FH, 09H, 01H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (Universal Non-realtime Message)
7FH
Device ID (Broadcast)
09H
Sub ID#1 (General MIDI Message)
01H
Sub ID#2 (General MIDI 1 On)
F7H
EOX (End Of Exclusive)
* When this messages is received, this instrument will turn to the GM mode.
* Not received when the Receive GM1 System On parameter (SYSTEM/MIDI&USB) is
OFF.
❍GM2 System On
Status
Data byte
F0H
7EH 7FH 09H 03H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (Universal Non-realtime Message)
7FH
Device ID (Broadcast)
09H
Sub ID#1 (General MIDI Message)
03H
Sub ID#2 (General MIDI 2 On)
F7H
EOX (End Of Exclusive)
* When this messages is received, this instrument will turn to the GM mode.
* Not received when the Receive GM2 System On parameter (SYSTEM/MIDI&USB) is
OFF.
❍GM System Off
Status
Data byte
F0H
7EH, 7F, 09H, 02H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (Universal Non-realtime Message)
7FH
Device ID (Broadcast)
09H
Sub ID#1 (General MIDI Message)
02H
Sub ID#2 (General MIDI Off)
F7H
EOX (End Of Exclusive)
* When this messages is received, this instrument will return to the Performance mode.
●Universal Realtime System Exclusive Messages
❍Master Volume
Status
Data byte
F0H
7FH, 7FH, 04H, 01H, llH, mmH
Byte
Explanation
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
04H
Sub ID#1 (Device Control)
01H
Sub ID#2 (Master Volume)
llH
Master Volume lower byte
mmH
Master Volume upper byte
F7H
EOX (End Of Exclusive)
* The lower byte (llH) of Master Volume will be handled as 00H.
* The Master Level parameter (SYSTEM/GENERAL) will change.
Status
F7H
Status
F7H
Status
F7H
Status
F7H
157