LUBRICATION
39. Boom Extension Sheaves
Lube Type - EP-MPG
Lube Interval - 250 hours or 3 months
Lube Amount - Until grease extrudes
Application - 2 grease fittings
40. Main Hoist
Lube Type - AGMA EP-4
Lube Interval - Every 1000 hours or 12 months
Lube Amount - Capacity - 14.7 liters (15.5 quarts)
Application - Fill until level with the check plug opening.
41. Auxiliary Hoist
Lube Type - AGMA EP-4
Lube Interval - Every 1000 hours or 12 months
Lube Amount - Capacity - 14.7 liters (15.5 quarts)
Application - Fill until level with the check plug opening.
5-10
42. Hydraulic Reservoir
Lube Type - HYDO
Lube Interval - Check fluid level every 10 hours or daily,
using sight gauge on side of tank, with boom down and
all outrigger cylinders retracted; drain and refill as
necessary.
Lube Amount - 894 liters (236 gal.), to FULL mark on
sight gauge.
Application - Fill through breather/fill cap on top of tank.
When tank is drained, clean the magnetic pipe plug.
43. Hydraulic Filter
Change the filter when the indicator is red.
WIRE ROPE LUBRICATION
Wire rope is lubricated during manufacturing so that the
strands, and individual wires in strands, may move as the
rope moves and bends. A wire rope cannot be lubricated
sufficiently during manufacture to last its entire life.
Therefore, new lubricant must be added periodically
throughout the life of a rope to replace factory lubricant which
is used or lost. For more detailed information concerning the
lubrication and inspection of wire rope, refer to WIRE ROPE
in Section 1- INTRODUCTION in the Service Manual.