Table A12 - Roll-Control2 - Advanced parameters
Parameter
The parameter should be modified only when
155 - Motor
using electric curtains or low-power motors!
operation
The power threshold is interpreted as reach-
detection
ing the limit switch.
This parameter determines the time needed
to reach the full opening.
156 – Time of
The value is set automatically during the cali-
up movement
bration process. It should be manually set in
case of problems with the autocalibration.
This parameter determines the time needed
to reach full closure.
157 – Time of
down move-
The value is set automatically during the cali-
ment
bration process.It should be manually set in
case of problems with the autocalibration.
158 – Virtual
This parameter enables you to set a fixed
limit switch.
minimum level of lowering the shutter.
The pot pro-
For example, to protect a flowerpot located
tection
on a windowsill.
159 – Favorite
This parameter enables you to define your
position -
favorite aperture level.
opening level
This parameter enables you to define your
160 – Favorite
favorite position of the slat angle.
position - slat
The parameter is used only for venetian
angle
blinds.
16
Description
Size
Default Value
2 [byte]
2 (2 W)
600
2 [byte]
(60 seconds))
1 [byte]
0 (default value)
50 (default
1 [byte]
value)
Available Values
0 - reaching the limit switch isn't detected. In
this case parateter 150 Calibration is set to 4 -
Manual calibration.
You need to correct the time manually in pa-
rameters 156 and 157.
1 - 255 (1 - 255 W) - end switch detection
0 - 65535
(0 - 6553.5 s, every 0.1 s) - time of turn
0-99
0-99
0xFF - Functionality disabled