Resetting To Factory Defaults; Energy Metering - Nice Roll-Control2 Instructions And Warnings For Installation And Use

Remote control of roller blinds, venetian blinds, pergolas, curtains, awnings and blind motors with electronic or mechanical limit switches

Advertisement

9
MENU
Using the in-built device menu you can calibrate the device or perform factory reset.
To use the in-built device menu:
1. Switch off the mains voltage (disable the fuse).
2. Remove the device from the wall switch box.
3. Switch on the mains voltage.
4. Press and hold the PROG button to enter the menu.
5. Wait for the LED indicator to indicate the desired menu position with color:
• BLUE - autocalibration
• YELLOW - factory reset
6. Quickly release and click the PROG button again.
7. After clicking the PROG button, the LED indicator confirms the menu position by blinking.
10

RESETTING TO FACTORY DEFAULTS

The reset procedure enables you to restore the device back to its factory settings, which means all information about the Z-Wave controller and
a user's configuration is deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
1.
Switch off the mains voltage (disable the fuse).
2.
Remove the device from the wall switch box.
3.
Switch on the mains voltage.
4.
Press and hold the PROG button to enter the menu.
5.
Wait for the LED indicator to glow yellow.
6.
Quickly release and click the PROG button again.
7.
During the factory reset, the LED indicator blinks yellow.
8.
After a few seconds the device is restarted, which is signalled with the the red color of the LED indicator.
11

ENERGY METERING

The device enables the energy consumption monitoring. Roll-Control2 reports energy consumption, but doesn't report instantaneous power.
Data is sent to the main Z-Wave controller.
Measuring is carried out by the most advanced micro-controller technology, assuring maximum accuracy and precision (+/- 5% for loads greater
than 10 W).
Electric energy – energy consumed by a device through a time period. Consumers of electricity in households are billed by
suppliers on the basis of active power used in given unit of time. Most commonly measured in kilowatt-hour [kWh]. One kilowatt-
hour is equal to one kilowatt of power consumed over period of one hour, 1 kWh = 1000 Wh.
Resetting consumption memory:
The consumption memory reset can be initiated through the hub interface (BUI) or Z-Wave controller using Meter CC.
The consumption memory reset is also carried out, during the reset to factory defaults procedure.