Download Print this page

Flowserve Logix 3400IQ User Instructions page 48

Digital positioner
Hide thumbs Also See for Logix 3400IQ:

Advertisement

4
Logix 3400IQ Digital Positioner FCD LGENIM3402-00 – 0/07
Table 8.5 Transducer Block Parameters
In-
Fieldbus Parameter Name
dex
88
HALL_NULL
89
HALL_DOWN
90
HALL_UP
91
POSALERT_HIGH
92
POSALERT_LOW
93
POSDEV_DEADBAND
94
POSDEV_TIME
95
SIG_START
96
SIG_STOP
97
RAMP_RATE
98
STEP_TIME
99
SIG_FLAGS
100
SAMPLE_TIME
101
SIG_COUNTER
102
INTAD_RAW1
103
INTAD_RAWTP
104
INTAD_RAWBP
105
INTAD_RAW3
106
INTAD_RAW4
107
INTAD_RAW5
108
INTAD_RAW6
109
INTAD_RAW8
110
TEST_MODE
111
VALVE_SIZE
112
VALVE_CLASS
113
VALVE_ENDCON
114
VALVE_BODYMAT
115
VALVE_TRIMMAT
116
VALVE_TRIMCHAR
117
VALVE_TRIMTYPE
118
VALVE_TRIMNO
119
VALVE_PACKTYPE
120
STEM_DIAM
121
LEAK_CLASS
122
INLET_PRESS
123
OUTLET_PRESS
124
VALVE_FLAGS
125
RATED_TRAV
126
ACT_TYPE
127
ACT_SIZE
128
SPRING_TYPE
129
SPOOL_ID
130
PO_DATE[8]
131
INSTALL_DATE[8]
132
LOAD_EE_DEFAULTS
133
ENG_RELEASE_NUM
134
MISC_FLAGS
Manufacturer Specific Parameters - Owned by Fieldbus Processor
135
SIG_INDEX
136
SIG_DATA[4]
137
MFG_PHONE[18]
138
PUR_ORDER_NUM[18]
139
STROKE_TIME_OPEN
140
STROKE_TIME_CLOSE
Fieldbus
Storage
Read/ Write
Datatype
Unsigned16
S
R/W*
Unsigned16
S
R/W*
Unsigned16
S
R/W*
float
S
R/W
float
S
R/W
float
S
R/W
float
S
R/W
float
N
R/W*
float
N
R/W*
float
N
R/W*
float
N
R/W*
Unsigned8
N
R/W*
float
N
R/W*
Unsigned16
D
R
Unsigned16
D
R
Unsigned16
D
R
Unsigned16
D
R
Unsigned16
D
R
Unsigned16
D
R
Unsigned16
D
R
Unsigned16
D
R
Unsigned16
D
R
Unsigned8
D
R/W*
Unsigned8
S
R/W
Unsigned8
S
R/W
Unsigned8
S
R/W
Unsigned8
S
R/W
Unsigned8
S
R/W
Unsigned8
S
R/W
Unsigned8
S
R/W
Unsigned8
S
R/W
Unsigned8
S
R/W
float
S
R/W
Unsigned8
S
R/W
float
S
R/W
float
S
R/W
Unsigned8
S
R/W
float
S
R/W
Unsigned8
S
R/W
Unsigned8
S
R/W
Unsigned8
S
R/W
Unsigned8
S
R/W
Visible
S
R/W
String
Visible String
S
R/W
Unsigned8
D
R/W*
Unsigned16
S
R
Unsigned8
N
R/W*
Unsigned16
D
R/W
float[4]
D
R
Visible
S
R/W
String
Visible
S
R/W
String
float w/sta-
S
R/W
tus
float w/sta-
S
R/W
tus
Access
Notes, Default
Type
Values
Diag
150
Diag
250
Diag
50
Info-2
110
Info-2
-10
Info-2
2
Info-2
60
Info-3
0
Info-3
100
Info-3
200
Info-3
10
Info-3
Info-3
0,1
Info-3
Diag
Diag
Diag
Diag
Diag
Diag
Diag
Diag
Info-2
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
Uninitialized
Info-2
MMDDYYYY
Info-2
MMDDYYYY
Info-2
Info-1
Info-2
Honeywell
Honeywell
Honeywell
Honeywell

Advertisement

loading
Need help?

Need help?

Do you have a question about the Logix 3400IQ and is the answer not in the manual?