  • Page 1 TECHNICAL BULLETIN Logix 3000MD Series Digital Positioner Experience In Motion...
  • Page 2 The Logix 3000MD series positioners offer valve status updates at a glance using the highly visible LEDs. Users can easily determine if a valve or actuator is functioning properly, and quickly diagnose any problems using the smart LED blink codes.
  • Page 3 By setting the Auto Tune on/off DIP switch, the tuning mode can be changed from auto to manual. The Logix 3000MD Series positioners provide several preset gain settings with a locally adjustable gain set selector directly from the user interface on the positioner.
  • Page 4 Flash Ram (Local Positioner Embedded Code Upgrade) Local Valve Signature Storage Local Calibration and Setup (While in OOS) 24/7 Local Fault Monitoring Flowserve is a Honeywell Partner, with Flowserve Local Adjustable Gain DTM support pending in the ExperionDCS Field Device Wizard/Method for On-line Commissioning Manager.
  • Page 5 Logix 3000MD Series Digital Positioner FCD LGENTB0059-01 – 10/09 The Logix 3200MD for HART Applications Complete local configuration, just like the Logix 3400MD, but HART protocol • Local status and alert messages • Tuning (Auto Tune function and manual adjustment) •...
  • Page 6 Logix 3200IQ Digital Positioner FCD LGENTB0059-01 – 10/09 The Logix 3000MD Series Positioners – no software or hand- held device required... easy as 1, 2, 3 With the Logix 3400MD, function blocks are no longer The Logix 3200MD can be set up with 10 VDC milliamp required to set up, configure and perform a simple stroke current supply current and 45 psi (min.) air supply on any...
  • Page 7 Logix 3000MD Series Digital Positioner FCD LGENTB0059-01 – 10/09 Time is Money Shorter commissioning time gets you up and running, making money faster Logix BONUS 3000MD Series Plant commission schedule Other digital positioners Time to Startup and Commission 3000MD Series Facts The local interface in the 3000MD series positioners and the two way communication capability allows the user to quickly commission loops.
  • Page 8 Logix 3200IQ Digital Positioner FCD LGENTB0059-01 – 10/09 There’s a Flowserve Expert Inside - ValveSight FDT/DTM Technology 21-P ’ lowserve alve ight soFtware helps Manage FielD Devices oinT haracTErizaTion urvE by coMbining the Features oF FielD network harDware anD the...
  • Page 9 Logix 3000MD Series Digital Positioner FCD LGENTB0059-01 – 10/09 Logix 3000MD Series Features List for ValveSight DTM 3200Md P 3400Md P alVe ight ogix oSitionerS ogix oSitionerS Dashboard All-Alarm Annunciator Configuration Management Local Interface Control Position Cutoff Soft Limits Custom Stroke Characterization...
  • Page 10 Logix 3200IQ Digital Positioner FCD LGENTB0059-01 – 10/09 The Logix 3000MD Positioner Specifications Specifications for Logix 3400MD Table I: Electrical Specifications Table III: Physical Specifications Housing Two-wire, 9-32 VDC Cast, powder-painted aluminum or stainless steel Power Supply Material FF compatible Soft Goods Buna-N / Florosilicone Fisco compliant...
  • Page 11 Logix 3000MD Series Digital Positioner FCD LGENTB0059-01 – 10/09 The Logix 3000MD E.O.M. Mounting Kits Brand Model Size Mounting Kit Brand Model Size Mounting Kit 213905 173298 0.5" – 1.5" stroke 141410 173298 0.5" – 1.5" 171516 stroke 173298 657 & 667 171517 2"...
  • Page 12 Logix 3200IQ Digital Positioner FCD LGENTB0059-01 – 10/09 3000MD Series dimensions NOTE: Dimensions in inches (mm)
  • Page 13 Logix 3000MD Series Digital Positioner FCD LGENTB0059-01 – 10/09 How to order Selection Code Example HART Protocol Foundation Fieldbus Standard (No Sensors) Diagnostics Advanced (With Sensors) Pro Diagnostics (with sensors and full ValveSight dianostics) Aluminum, White Paint (Valtek) Stainless Steel, No Paint (Valtek)
  • Page 14 Logix 3200IQ Digital Positioner FCD LGENTB0059-01 – 10/09 Logix 3400MD Hazardous Area Certifications Certification Enclosure Notified Body Approval Entity Parameters Temperature Code Option Rating Explosionproof: Class I, Div 1, Groups B,C,D NEMA Not Applicable T6 T ≤ = 60ºC Dust Ignition Proof: Class II, III, Div 1, Groups EFG (See Warning No.
  • Page 15 Logix 3000MD Series Digital Positioner FCD LGENTB0059-01 – 10/09 Logix 3200MD Hazardous Area Certifications Certification Enclosure Notified Body Approval Entity Parameters Temperature Code Option Rating Explosionproof: Class I, Div 1, Groups B,C,D NEMA Dust Ignition Proof: Not Applicable T6 T ≤...
  • Page 16 Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions.