IPL EXP I/O Series Expansion Interface Reset Mode Summary
Use This
Activation
Mode to...
Reset IP
To reset all network settings:
settings and
1. Press and hold the
port maps
LED blinks once at 3 seconds and twice at 6 seconds.
to factory
2. Release and press the
defaults
<1 second) within 1 second*. The LED blinks 3 times in
without
quick succession upon successful reset.
affecting user-
* Nothing happens if the momentary press does not occur
loaded files
within 1 second.
Start over with
To reset the unit to all factory default settings:
configuration
1. Hold down the
and uploading
blinks once at 3 seconds, twice at 6 seconds, and
three times at 9 seconds.
2. Release and press the
<1 second) within 1 second*. The Reset or Power LED
blinks 4 times in quick succession upon successful reset.
* Nothing happens if the momentary press does not occur
within 1 second.
NOTES:
•
After performing a Reset All Network Settings or Full Factory Reset reset, either set the IP address again
(by using Toolbelt) for use on your network, or turn DHCP on.
•
The factory configured passwords for this device have been set to the device serial number. Passwords
are case sensitive. Performing a Full Factory Reset sets the password to
Reset
button until the Reset or Power
Reset
button momentarily (for
Reset
button until the Reset or Power LED
Reset
button momentarily (for
IPL EXP I/O Series • Hardware Features and Installation
Result
Reset All Network Settings mode:
Turns DHCP off.
•
Sets the IP address back to factory
•
default:
LAN port: 192.168.254.250
Sets the subnet back to factory default
•
(255.255.255.0).
Sets the default gateway address to the
•
factory default (0.0.0.0).
Sets domain and host names to factory
•
default.
Sets port mapping back to factory default.
•
Turns events (user-created schedules,
•
macros) off.
Stops any running program.
•
Disables 802.1X authentication.
•
Full Factory Reset mode performs a
complete reset to factory defaults (except
the firmware).
Does everything Reset All Network
•
Settings mode does.
Removes (clears) all user-loaded files
•
(except LinkLicense files) and
configurations from the control processor:
Clears driver-port associations
•
(IR, serial, Ethernet) and port
configurations.
Removes button/touchpanel
•
configurations.
Removes user-loaded digital
•
certificates.
Removes schedules, settings, macros.
•
Clears messages in the event logs
•
table.
The unit continues to run the user-loaded
•
firmware.
extron
.
28
Need help?
Do you have a question about the IPL EXP I/O Series and is the answer not in the manual?