7.2.2.
Parameter Settings
Set the IP address of the Indicator.
The Switch on the front panel is used to set parameters.
Refer to 2 Settings/operations of the FC400-EIP OPERATION MANUAL (18AUG2021) for
more information on changing the setting items by using the Switch.
1
Check the positions of Main
Display and Switch on Indicator.
2
Turn ON Indicator.
3
The weight value is shown on
Main Display.
Press F (FNC key).
*The mode of Indicator is
changed from weighing mode
to setting mode.
4
F0 (setting mode 0) is
displayed.
Press
(TARE key) seven
times.
*The digit flashes when
changing the mode of Indicator
to setting mode.
"F7" (setting mode 7) is
displayed.
Press △ (ZERO key).
*"F7" (setting mode 7) is to set
the IP address and subnet
mask.
7.EtherNet/IP Connection Procedure
Main Display
FNC
TARE
ZERO
ENT(G/N)
RESET
8.
. .
. 8.8.
Setting mode number
"F" display
. 8.8
Switch
Main Display
17