W Cooling fan
setting
The transceiver has a heatsink and cooling fan to radiate
heat.
The cooling fan automatically turns ON. while trans-
mitting and remains ON for 2 min. after transmitting.
The
cooling fan can be activated continuously, if desired.
INITIAL SET mode
The display shows that the
The display shows that the
cooling fan operates auto-
cooling fan operates contin-
matically.
uously.
@ Push [POWER] for 2 sec. to turn power OFF.
© While pushing [SET], turn power ON to enter initial set
mode.
© Push [SET] or [S.MW] one or more times to select the
"FAn" display as shown above.
@ Rotate the VHF tuning dial to set the cooling fan to
automatic ("At") or continuously ("on").
© Turn power OFF to exit initial set mode.
'Mi Mono band operation
One of the bands can be deactivated to simplify operation.
@ Turn the power OFF.
@ While pushing a band's tuning dial, turn the power ON to
deactivate that band.
- To activate the masked band, turn power ON while pushing
the deactivated band's tuning dial.
W Demonstration display
A demonstration function is available at power ON.
This
function gives you a quick visual introduction to the function
display indicators.
@ While pushing
[SET] and either VHF
or UHF
[VOL],
push [POWER] for 2 sec. to turn power ON.
- The transceiver cycles through a visual tour of the function
display indicators.
@ Push any switch to exit demonstration mode and enter
the normal operating condition temporarily.
- The transceiver automatically returns to demonstration mode
after 2 min. in which no operations are performed.
- The condition
remains activated even
when the power is
turned OFF and ON again. Perform step @ to cancel.