Hot foil printer with controller

Advertisement

Sprint Major - Digi60
DIGI-60 System Fault Indications
Thermistor - Short circuit
Red thermistor fault LED lit.
Internal beeper sounding.
Display shows "2.6.5" (or similar value).
Heater disabled.
Thermistor - Open circuit
Red thermistor fault LED lit.
Internal beeper sounding.
Display shows ". 1.0" (or similar value).
Heater disabled.
Heater - Open circuit
Red heater fault LED lit.
Internal beeper sounding.
Foil - Run out or broken
Red foil fault LED lit.
Internal beeper sounding.
Type holder door open
This feature is not available on Sprint Major.
Air pressure - Low
Red heater fault LED lit.
Internal beeper sounding.
Note! Low air pressure warning uses an optional pressure
In any of the above fault conditions, the fault relay will be de-energised. See pages 19 & 20 for