Safety Precautions/Site Preparation - Perlick CC24B-2 Installation & Operation Manual

Column refrigeration
Table of Contents

Advertisement

PLEASE READ all instructions completely before
attempting to install or operate the unit. Take
particular note of the DANGER, WARNING an
CAUTION information in the manual. The information
is important for the safe and efficient installation,
operation and care of your Perlick unit.
Indicates a hazard
DANGER
that WILL result in
serious injury or death if precautions
are not followed.
Read and understand all information in this manual before attempting the installation.
All electrical work must be performed by a qualified technician and
WARNING: California Prop 65 Notice
These products may expose you to chemicals including Chromium, which are known to the state of California to cause cancer
and birth defects or other reproductive harm. For more information on whether a product in this list contains these chemicals,
please refer to the specific product page at perlick.com. Or to find out more about Prop 65, go to P65Warnings.ca.gov.
Carefully inspect the cabinet
WARNING
for hidden damage. If
damage is discovered, file your claim immediately
with the transportation company. Perlick is not
responsible for damage in transit.
When moving the unit, be
CAUTION
sure to protect finished
flooring with appropriate material to avoid
damage from moving the appliance.
If unit has been laid on its
CAUTION
back or sides, place unit
upright and allow minimum of 24 hours before
connecting the unit. Failure to do so can affect
the function and performance of the appliance.
This appliance should be installed in a dry, ventilated
indoor location. The ambient temperature of the
location must be between 55°F (13°C) and 100°F
(43°C) for optimal performance.
Column Refrigeration Installation & Operation Manual
SAFETY
IMPORTANT!
conform to all applicable state and local codes.
SITE PREPARATION
3
Indicates a hazard MAY
WARNING
cause serious injury or
death if precautions are not followed.
Indicates a hazard w
CAUTION
here minor injury or
product damage may occur if precautions
are not followed.
Indicates that property
NOTICE
damage may occur if
warnings or instructions are not followed.
When fully stocked, Perlick wine column refrigeration
is very heavy. To ensure safety and prevent home
damage, the load-bearing capacity of your floor
must be 550 lbs.capacity for 24", and 650 lbs.
capacity for 30" column units being installed.
This product must be installed on a level floor for
safety and optimal performance. The base must be
flat to ensure anti-tip brackets properly function and
that the refrigeration system is level. Any walls and
surrounding furniture/fixtures need to be securely
attached to the floor, wall studs or concrete prior to
installing the column.
To ensure proper performance, the air intake (toe
kick) must not be blocked and condenser divider
installed. Perlick refrigeration is front-breathing, and
covering the intake, or failure to install the condenser
divider will cause the system to overheat and fail.