Column Refrigeration Installation & Operation Manual
Custom Overlay Panels
A custom door panel and handle hardware must
be installed if a customer chooses to not purchase
a Perlick stainless steel door panel. The thickness
of the custom panel can vary. A minimum 5/8"
(16) thick panel is required, but the thickness can
be increased provided it does not exceed the
maximum panel weight of 65 lbs (29). 3/4" panel is
recommended. Please note that the combined door
and overlay weight cannot exceed 120 lbs (54). The
depth of each model is 24" (610). Allow for panel
thickness when planning the finished opening depth.
Templates for glass doors with 4" or 6" toe kicks can
be found starting on page 17.
As reveals between
CAUTION
cabinetry and the unit
decrease, severe finger pinching can occur
while the door is closing.
The height of the custom door panel can extend
beyond the typical panel height provided it does not
exceed the weight limit listed above.
Do not install a solid
CAUTION
overlay panel onto the
front of a glass door model. Condensation
will form between the glass and the overlay
panel, which will cause damage to custom
cabinetry.
INSTALLING DOOR OVERLAY PANELS CONTINUED