Retry Counts
This function is used to set the number of retries for communications before an error screen
will be displayed, when a communications error occurs while communicating with the host.
If communications are still unsuccessful even after the number of communications retries
specified here have been executed, the process set for the communications auto return will
be executed.
The number of retries can be set to between 0 and 255 times. The default setting is 5 retries.
Set the communications auto-return by using operations from the Comm. Tab Page as
follows.
1. Input the value by using the Up and Down buttons or the keypad that are displayed by
clicking the Keyboard Button.
2. After setting, click the Write Button to save the setting. (For details on the write button,
refer to Writing on page 5-29.)
3. The settings are enabled after the NS-Runtime is restarted.
Serial A / Serial B
This function is used to display and set whether to use the serial ports A /B and the
communications conditions.
N
o
t
e
N
o
t
e
N
o
t
e
The NS-Runtime supports the host link and toolbus when the serial ports A/B is used for
the communications.
Host Link connections are not supported for CJ2 CPU Units.
Make the settings for the serial port A by using operations from the Comm. Tab Page as
follows.
In the same way, make the settings for the serial port B.
1. Select the Disable / Enable for the Serial A.
2. When selecting the Enable, set and display the details of serial port A.
5-6 Initialization/Setting Screen
5-39