Part Names And Functions - Omron ZX-T Operation Manual

Zx-t series smart sensors
Hide thumbs Also See for ZX-T:
Table of Contents

Advertisement

Part Names and Functions

Amplifier Units
Display area ( )
(1) Input cable
(1) The input cable connects the Sensor Head.
(2) The current/voltage switch selects either a current or voltage linear output.
Monitor focus settings are also required when switching the output.
(3) The connectors connect Calculation and Interface Units.
(4) The output cable connects to the power supply and external devices, such as sync sensors or
programmable controllers.
(5) The Power ON indicator lights when the power is turned ON.
(6) The Zero Reset indicator lights when the zero reset function is enabled.
(7) The ENABLE indicator lights when the measurement result is within the rated measurement
distance.
(8) The HIGH indicator lights when the judgement result is HIGH.
(9) The PASS indicator lights when the judgement result is PASS.
(10) The LOW indicator lights when the judgement result is LOW.
(11) The main display shows measured values and function names.
(12) The sub-display shows additional information and function settings for measurements.
Reading Displays, p. 43
(13) The threshold switch selects whether to set (and display) the HIGH or LOW threshold.
(14) The mode switch selects the operating mode.
(15) The Control Keys set measurement conditions and other settings.
Key Operations, p. 44
PREPARATIONS FOR MEASUREMENT
Controls ( )
(3) Connectors (one on each side, two total)
(2) Current/voltage switch (back of Unit)
(5) Power ON indicator
Details of Controls
and Display Area
(8) HIGH indicator
(9) PASS indicator
(10) LOW indicator
(11) Main display
(12) Sub-display
Current/voltage
output selector
Voltage output
Current output
(4) Output cable
(6) Zero reset indicator
(7) ENABLE indicator
(14) Mode switch
(13) Threshold switch
Switching Modes, p. 42
Section 2
(15) Operating Keys
p. 81
ZX-T
21
Operation Manual