APPENDICES
Power supply voltage
Current consumption
Connectable Amplifier Units
No. of Amplifier Units con-
nectable
Communica-
Communica-
tions functions
tions port
Protocol
Baud rate
Data config-
uration
Indicators
Protection circuits
Ambient temperature
Ambient humidity
Dialectic strength
Insulation resistance
Case materials
Weight (packed state)
ZX-T
130
Operation Manual
12 to 24 VDC ± 10%, Ripple (p-p) 10% max.
Supplied from Amplifier Unit
Power supply voltage: 12 V, Current consumption: 60 mA max.
(Excluding Amplifier Unit current consumption and output current.)
ZX Series
Up to 5 (Two Calculating Units max.)
RS-232C port (9-pin D-sub connector)
CompoWay/F
38,400 bps
Data bits: 8, Parity: None; Start bits: 1
Stop bits: 1, Flow control: None
Power ON (green), Communicating with Sensor (green), Sensor communications
error (red)
Communicating with external terminal (green), External terminal communications
error (red)
Reverse power supply wiring protection
Operating: 0 to 50 ° C, Storage: − 15 to 60 ° C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
1,000 VAC, 50/60 Hz for 1 min
20 M Ω min. (at 500 VDC)
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Approx. 350 g