Section 4
Inspecting by Brightness (BRIGHT)
■ Adjusting the threshold level
● Switching to
ADJ mode
ADJ
MENU
RUN
Upper/lower limit
Setting item
Average
density value
Density devi-
ation value

CUSTOM Menu

Items that can be customized
Items related to
brightness
Items related to
color
ZFV-C
82
User's Manual
● Adjustment of aver-
age density value
BRIGHT
OK
200
L: [ 200] H:[ 220] A
Lower limit
Upper limit
LEFT/RIGHT keys: Select upper limit/
lower limit.
UP/DOWN keys:
Change values.
Range
0 to 255
Threshold level for the average density in the teaching area.
0 to 127
Threshold level for the density deviation in the teaching area.
Items that can be customized
Changing the detection content
Changing the filter color
● Adjustment of den-
sity deviation value
BRIGHT
Measured
values
L: [ 30] H:[ 60] D
Upper/lower limit Lower limit
LEFT/RIGHT keys: Select upper limit/
UP/DOWN keys:
Details of Adjustment
OK
Measured
50
values
Upper limit
lower limit.
Change values.