Installing The Sensor Head - Omron ZFV-C Manual

Smart sensor with ultra-high-speed color ccd cameras
Hide thumbs Also See for ZFV-C:
Table of Contents

Advertisement

Installing the Sensor Head

This section describes how to install the Sensor Head.
■ Setting distance
The following graphs show the relationship between detection range and setting dis-
tance for each model of Sensor Head.
Values differ according to each model of Sensor Head, so check the model before
using these graphs.
• ZFV-SC10
Setting distance L (mm)
100
30
4
• ZFV-SC50
Setting distance L (mm)
190
100
30
9 10
Workpiece
Detection range H
10
Detection range H (mm)
50
Detection range H (mm)
Setting distance L
Detection range H (mm) Setting distance L (mm)
5
34
6
37
7
40
8
44
9
49
Detection range H (mm) Setting distance L (mm)
10
31
15
51
20
70
25
90
30
109
35
128
40
148
45
167
50
187
Section 2
Sensor Head
ZFV-C
47
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zfv-c series

Table of Contents