When Gang-mounting Amplifier Units

Application examples of amplifier unit gang-mounting and caution notes are explained.

Gang-mounting example

■ 1 sensor head + multiple amplifier units
Example of detection of input image from 1 sensor head with multiple amplifier units.
•To detect multiple areas such as a 4-sided POSITION, multiple item SEARCH, etc.
•To detect multiple types such as both SEARCH and AREA judgments.
ENABLE signal
■ Multiple sensor heads + multiple amplifier units
Example of synchronizing and detecting multiple points of the same workpiece and
integrating judgments.
ENABLE signal
When Gang-mounting Amplifier Units
Images are transferred from
right-side to left-side amplifier
units.
TRIG signal
Measured with images loaded
from each sensor head.
TRIG signal