ZX SERIES

Amplifier Units

Item
Measurement period
Possible average count settings
(See Note 1)
Temperature characteristic
Linear output (See Note 2)
Judgement outputs
(3 outputs: HIGH/PASS/LOW)
(See Note 1)
Laser OFF input, zero reset
input, timing input, reset input
Functions
Indications
Power supply voltage
Current consumption
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance (destruction) 10 to 150 Hz, 0.7 mm double amplitude 80 min each in X, Y, and Z directions
Shock resistance (destruction)
Connection method
Weight (packed state)
Materials
Accessories
Note:
1. The response speed of the linear output is calculated as the measurement period x (average count setting +1)
(with fixed sensitivity).
The response speed of the judgement outputs is calculated and the measurement period x (average count setting + 1)
(with fixed sensitivity).
2. The output can be switched between a current output and a voltage output using a switch on the bottom of the amplifier unit.
3. Setting is possible via the monitor focus function.
4. A calculating unit is required.
Part number
ZX-LDA11
150 µs
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096
When connected to a Reflective Sensor Head: 0.01% FS/°C, When connected to a Through-beam
Sensor Head: 0.1% FS/°C
4 to 20 mA/FS, Max. load resistance: 300 Ω, ±4 V [± 5 V, 1 to 5, 0 to 5 VDC (See Note 3)],
Output impedance: 100 Ω
NPN open-collector outputs, 30 VDC, 50 mA max.
Residual voltage: 1.2 V max.
ON: Short-circuited with 0-V terminal or 1.5 V or
less
OFF: Open (leakage current: 0.1 mA max.)
Measurement value display, set value/light level/resolution display, scaling, display reverse, display OFF
mode, ECO mode, number of display digit changes, sample hold, peak hold, bottom hold, peak-to-peak
hold, self-peak hold, self-bottom hold, intensity mode, zero reset, initial reset,
ON-delay timer, OFF-delay timer, one-shot timer, deviation/sensitivity adjustment, keep/clamp switch,
direct threshold value setting, position teaching, 2-point teaching, automatic teaching,
hysteresis width setting, timing inputs, reset input, monitor focus, (A-B) calculations (See Note 4), (A+B)
calculations (See Note 4), mutual interference (See Note 4), laser deterioration detection, zero reset
memory, key lock
Operation indicators: High (orange), pass (green), low (yellow), 7-segment main display (red),
7-segment subdisplay (yellow), laser ON (green), zero reset (green), enable (green)
12 to 24 VDC ±10%, Ripple (p-p): 10% max.
200 mA max. (with Sensor connected)
Operating: 0 to 50°C, Storage: −15 to 60°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. at 500 VDC
1,000 VAC, 50/60 Hz for 1 min
2
300 m/s
3 times each in six directions (up/down, left/right, forward/backward)
Prewired (standard cable length: 2 m)
Approx. 350 g
Case: PBT (polybutylene terephthalate), Cover: Polycabonate
Instruction sheet
ZX-LDA41
PNP open-collector outputs, 30 VDC, 50 mA max.
Residual voltage: 2 V max.
ON: Supply voltage short-circuited or supply
voltage within 1.5 V
OFF: Open (leakage current: 0.1 mA max.)