Omron ZFV - V2.0 User Manual page 40

Ver 2.0 smart sensors
Table of Contents

Advertisement

• ZFV-SR50
Setting distance L (mm)
300
100
30
9 10
(Example)
When using a ZFV-SR50 Sensor Head at
a detection range of 25 mm required for
the location of the sensing object, the set-
ting distance of Sensor Head becomes
95mm.
About installation for reflective workpieces
Install the Sensor Head at an angle to prevent mirror reflection light from being picked
up by the sensor.
ZFV
User's Manual
60
Detection range H (mm)
Mirror reflec-
tion light
Guide light
Detection range H
(mm)
10
15
20
25
30
35
40
45
50
Workpiece
Detection range H
Section 2
Sensor Head
Setting distance L
(mm)
38
57
76
95
115
134
157
174
194
Setting
distance L
39

Hide quick links: