• ZFV-SR50
Setting distance L (mm)
300
100
30
9 10
(Example)
When using a ZFV-SR50 Sensor Head at
a detection range of 25 mm required for
the location of the sensing object, the set-
ting distance of Sensor Head becomes
95mm.
●
About installation for reflective workpieces
Install the Sensor Head at an angle to prevent mirror reflection light from being picked
up by the sensor.
ZFV
User's Manual
60
Detection range H (mm)
Mirror reflec-
tion light
Guide light
Detection range H
(mm)
10
15
20
25
30
35
40
45
50
Workpiece
Detection range H
Section 2
Sensor Head
Setting distance L
(mm)
38
57
76
95
115
134
157
174
194
Setting
distance L
39