Control Screens

3-6

Control Screens

3-6-1 Outline

Block name (mode)
Target function
1-Block Send Terminal to
block
Computer (403)
4-Block Send Terminal to
Computer (404)
AO to Computer (402), AO
Terminal to All Nodes (408)
DO to Computer (401), DO
Terminal to All Nodes (407)
AO Terminal Settings from
Computer (410)
DO Terminal Settings from
Computer (409)
Display
Setting
44
Use Control Screens to monitor and set the Control Block and part of the Opera-
tion Block, to monitor analog signals, and to monitor and set contact signals. For
the Control Block in particular, use the Control screen to perform such opera-
tions as monitoring Set Point (SP), Process Variable (PV), Manipulated Variable
(MV) run status, and Set Point (SP) changes, etc.
Click the Control Screen Button in the Overview screen to display the following
information on the Control Screen.
• You can display up to a maximum of eight loops per screen of PID, Indica-
tors, and other Control Blocks as on-site Instrument images. The maxi-
mum is 400 screens x eight loops.
• You can perform SP changes, auto/manual switching, and manual opera-
tions, etc. (Items indicated by a Button can be changed. Items without a
Button are displayed only.)
• You can also move to the Tuning Screen.
Control Block: Basic PID (011), Advanced PID (012), Batch
flowrate capture (014), Indication and Setting (031), Indication and
Operation (032), Ratio Setting (033), Indicator (034), blended PID
(013), 2-position ON/OFF (001), 3-position ON/OFF (002)
Control Block: Basic PID (011), Advanced PID (012), Indication
and Setting (031), Indication and Operation (032), Ratio Setting
(033), Indicator (034), 2-position ON/OFF (001), 3-position
ON/OFF (002)
Operation Block: High/Low Alarm (111), Segment Program 2(157),
ON/OFF Valve Manipulator (221), Motor Manipulator (222),
Reversible Motor Manipulator (223), Motor Opening Manipulator
(224), Timer (205), Counter (208)
Analog input signals or analog output signals for all function
blocks, or analog value parameters
Contact input signals or contact output signals for all function
blocks, or contact value parameters
Analog output ITEM for AO Terminal Settings from Computer
(Used to set ordinary analog values. Displays using network
resend monitoring.)
Contact output ITEM for DO Terminal Settings from Computer
(Used to set ordinary contact values. Displays using network
resend monitoring.)
SP, PV, MV, A/M status, R/L status (See note 1), bar color change
analog signal when an alarm occurs, contact signal
SP, MV (only in manual mode), A/M switching (See note 3), R/L
switching (See note 1 and note 2)
Contact signal (See note 4)
Note
1. When the SP setting (local only, or remote/local both possible) for ITEM024
for Basic PID, Advanced PID, Indication and Setting, Ratio Setting, 2-posi-
tion ON/OFF, and 3-position ON/OFF is 1 (remote/local both possible), CAS
is displayed. If the setting is 0 (local only), nothing is displayed.
2. When the SP setting (local only, or remote/local both possible) for ITEM024
for Basic PID, Advanced PID, Indication and Setting, Ratio Setting, 2-posi-
tion ON/OFF, and 3-position ON/OFF is 1 (remote/local both possible), CAS
is displayed, and settings can be made.
3. When set to remote, only auto is possible; manual is disabled (this limit only
applies to CX-Process Monitor).
4. Analog signals are not possible.
Send source function block, or ITEM
Section
3-6