SECTION 6
Appendix
Specifications and Dimensions
Controller
V700-L22
Power indicator
Indicators
Item
Power supply voltage
Current consumption
Ambient temperature
Ambient humidity
Degree of protection
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ground
Case material
Weight
CIDRW System
104
User's Manual
150
130
P6X3
30
24 VDC +10% -15%
150 mA max. (inrush current: approx. 10 A max.)
Operating: 0 to +40°C
Storage: -15 to +65°C (with no icing)
Operating: 10% to 85%
Storage: 10% to 95% (with no condensation)
IP20 (IEC60529)
50 MΩ min. between power supply terminals and the frame ground terminal (500 VDC M)
Leak current not to exceed 3.5 mA on application of 500 VAC (50/60 Hz for 1 minute) between both
power supply terminals and the frame ground terminal
Frequency: 10 to 150 Hz; double amplitude: 0.20 mm; acceleration: 15 m/s
8 minutes, 10 times each in X, Y, and Z directions
Shock of 150 m/s
in X, Y, and Z directions, 3 times each for 18 repetitions
2
Ground to 100 Ω or less.
SECC (coating)
Approx. 580 g
28
Mounting dimensions
(1:2)
7
(mounting holes)
Four, 4.5-dia. holes
4-φ4.5
Specifications
(Unit: mm)
130±0.2
4-M4
2
for