Noise Measurement - Omron V640 - MANUAL 2 User Manual

V640 series
Hide thumbs Also See for V640 - MANUAL 2:
Table of Contents

Advertisement

■ NAK
Sends the response made immediately before again.
Command
SOH
Node No.
Command code
01h
1
Response
Sends the response made immediately before again.

■ Noise measurement

The levels of noise in the vicinity of the CIDRW Head are measured and the noise level is expressed
numerically in the range "00" to "99."
Command
SOH
Node No.
Command code
01h
4
Response
The response code (when normal: 00) and the noise level "00" to "99" are returned.
SOH
Node No.
Response code
01h
0
Influence of background noise on communication distance
■ RESET
All Amplifier Unit processing is stopped, and the initial status is re-established.
Command
SOH
Node No.
Command code
01h
7
Response
There is no response to this command.
FCS
CR
2
0Dh
FCS
CR
0
0Dh
Noise level
FCS
0
FCS
CR
F
0Dh
Reading from/Writing to ID Tags
CR
0Dh