Ratings and Specifications

Fiber Amplifier Units
Item
Sensing distance
Sensing object
Light source (wavelength)
Sensing method
Number of registered
colors
Power supply voltage
Power consumption
Control outputs
Number of control outputs
External input *3 (page 4)
Protection circuits
Super-high-speed mode *4
Response
High-speed mode
time
Standard mode
High-resolution mode
Sensitivity setting (color regis-
tration, allowable range)
Operation mode
Timer function
Control outputs
Functions
Remote control
Display switch *5
Initialization
Zero reset
Indicators
Digital display
Display direction
Ambient illumination (Receiver
side)
Ambient temperature range *6
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Case
Materials
Cover
Accessories
Note: Refer to page 4 for *1 to *6.
Arrow.com.
Arrow.com.
Arrow.com.
Downloaded from
Downloaded from
Downloaded from
Type
Standard models
Model E3X-DAC@-S@ (@: 11/41/6/8)
Depends on the Fiber Unit. Refer to page 5 to 7 for details.
Reflective models: Standard 11 color cards *1, Through-beam models: Opaque or translucent object
White LED (420 to 700 nm)
C Mode: RGB ratio determination (or I Mode: Light intensity determination for red, green, or blue;
Black Mode: Determination of total light intensity for red, green, and blue) *2
1
12 to 24 VDC ±10%, ripple (p-p) 10% max.
960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
NPN or PNP open collector
Load power supply voltage: 26.4 VDC max.
Load current: 50 mA max. (residual voltage: 2 V max.)
1
---
Reverse polarity for power supply connection, Output short-circuit, Reversed output polarity protection
Operate or reset: 60 μs
Operate or reset: 300 μs
Operate or reset: 1 ms
Operate or reset: 4 ms
Teaching (one-point teaching or teaching with/without workpiece) or manual adjustment
ON for match (ON for same color as registered color) or ON for mismatch (ON for different color from registered color)
Timer type: OFF delay, ON delay, or one-short, Timer time: 1 ms to 5 s (variable)
---
---
Seven patterns total: Match + Threshold, Margin + Threshold, Analog bar display, Peak + Bottom, etc.
Initial reset (factory defaults) or user reset (saved settings)
Supported
Operation indicator (orange)/I
mode display indicator (orange)
7-segment displays (Main display: Red, Sub-display: Green)
Switchable between normal and reversed.
Incandescent lamp: 3,000 lux
Sunlight: 10,000 lux
Operating: −25°C to 55°C, Storage: −30°C to 70°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. (at 500 VDC)
1,000 VAC at 50/60 Hz for 1 minute
Destruction: 10 to 50 Hz with a 1.5-mm double amplitude for 2 h each in X, Y and Z directions
2
Destruction: 500 m/s
, for 3 times each in X, Y and Z directions
IEC IP50 (with Protective Cover attached)
Pre-wired (standard cable length:
2 m) or reduced-wiring connector
(Units connected: 16 max.)
Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Polybutylene terephthalate (PBT)
Polycarbonate (PC)
Instruction manual
Advanced models with simultaneous
2-color determination
E3X-DAC@-S (@: 21/51)
2
(simultaneous determination)
2
Remote control
Operate or reset: 120 μs
Operate or reset: 600 μs
Operate or reset: 2 ms
Operate or reset: 8 ms
Output for each channel, AND output, and OR output
One-point teaching, teaching
with/without workpiece, zero
reset, and light emission OFF
Operation indicator for each channel (orange)
Pre-wired (standard cable length: 2 m)
E3X-DAC-S
Advanced models with
4-color determination
E3X-DAC@B-S (@: 21/51)
4
(2-color simultaneous
determination × 2 banks)
Bank switching
Bank switching
(switching between banks A
and B and banks C and D)
Initial reset (factory defaults)
Not supported
3