■ Byte Write
Writes data to any specified number of bytes starting from the address specified in the ID Tag.
The maximum number of bytes that can be written at one time is 128.
Command
SOH
Node No.
Command code
01h
0
4
* Data number n = number of bytes written to (2-character units)
Parameter description
Parameter
Address designation
Write data
Data Segment Area
Response
The response code (when normal: 00) is returned.
Response
SOH
Node No.
code
01h
0
Example: Writing to two bytes starting from address 05h of node No.1
Command
SOH
Node No.
01h
0
1
0
Response
Response
SOH
Node No.
code
01h
0
1
0
The ID Tag status on normal completion is as shown below.
Page 1
Page 2
First
address
Data 1
0
0
Addresses can be specified in the range 00h to 87h.
Up to 128 bytes of write data, starting from the specified address, can be specified.
Refer to page 129.
FCS
CR
0
0Dh
Command code
First address
4
0
0
0
FCS
CR
0
0
1
0Dh
12h
34h
Reading from/Writing to ID Tags
Write data
•••
Data n
Description
Write data
Data 1
Data 2
5
1
2
3
SECTION 4
FCS
CR
0Dh
FCS
CR
4
0
4
0Dh
CIDRW System
User's Manual