SECTION 3
Preparing for Communications

Change the response time-out time

In the initial settings of the CIDRW Controller, when ID Tag (RI-TRP-DR2B, made by Texas Instru-
ments) data is read or written, a response time-out may occur. Be sure to set the response time-out
time to 10 s.
The commands, and the parameters that can be set are indicated below.
List of Commands
Designation
Parameter designation
Parameter confirmation ::END
Comment
Tag Name List
Response time-out time
1.
Set the response time-out time to 10.0.
2.
Confirm the parameter change.
The input parameter is checked and written.
When writing is completed, a message indicating the result is displayed.
The ALARMS indicator lights.
If writing is completed with an error, the parameters are not updated.
The figure in square brackets [ ] indicates the line number where the
error was first detected. If a parity error is detected in the received char-
acters, this figure is [0].
Check the sent data based on this information.
CIDRW System
56
User's Manual
Command input
(Tag name) = (Set value) <CRLF> Specify the parameter value corresponding to the tag name.
# (Comment) <CRLF>
or
CRLF
Parameter
Tag name
RT
Checks the parameter designations that have been received so
far and, if there is no error, confirms the settings.
This is ignored as the comment line.
Setting range
10.0 (fixed)
RT=10.0
_
::END
_
When writing is completed without error
SETUP_COMPLETE
_
When writing is completed with an error
SETUP_FAILED [2]_
Explanation
Default setting
2.5