Problem
Probable cause
All  the  LED  of 
Teaching  data  setting  er-
the  threshold 
ror  
indicators    fla-
Buzzer 
The Sensor was set to  
shes  and  the 
sounds
MONITOR or RUN mode  
buzzer sounds.
before  teaching  comple-
1
ted.
This  LED  of 
Serial buffer overflow er-
the  threshold 
ror 
Buzzer 
indicators    fla-
Either the send buffer or 
sounds
shes  and  the 
receive  buffer  has  be-
buzzer sounds.
come full during commu-
1
nications.
A current exceeding the rated val-
Control  output  (OUTPUT) 
ue has flowed to the output transis-
and enable output are OFF, 
tor and the over-current protective 
and will not turn ON.
circuit has been triggered.
Detection Range type error
This  LED  of 
the  threshold 
Detection Range mode 
Buzzer 
indicators    fla-
currently set is different 
sounds
from that set in teaching.
shes  and  the 
buzzer sounds 
1
three times.
・ The  F10-S30R/S50R  can  not  detect  red  object  with  white  backgrounds. 
Use the F10-S15R/S05R inseead. 
・ The  F10-S15R/S05R  can  not  detect  green  object  with  white  backgrounds. 
Use the F10-S30R/S50R inseead. 
 
Remedy
Perform  the  teaching 
of  the  Sensor  in 
TEACH mode.
Refer to 1.Pattern 
Registration(TEACH  
Mode)on page 19.
Send  buffer  overflow  Change 
the communications settings. 
Receive buffer overflow 
Wait  for  a  response  from  the 
F10 then send the command.
Reduce  the  current  so 
that  it  will  not  exceed 
the rated value. 
Consult  your  OMRON 
representative,  when 
these signals do not be-
come ON even if reduc-
ing.
Perform again the teaching 
in TEACH mode or change 
the Detection Range mode.
 
          Refer  to
              4.1.
TEACH  mode.
 
59