7-segment LED
The 7-segment LED indicator is on the front panel.
When the power is turned on, it shows the node address that is set by the
rotary switches. Then the indication changes in accordance with the setting
on the Default Display (Pn700). If any alarming error occurs, it indicates the
error number (Errxxx) as the alarm code. If any warning situation occurs, it
indicates the warning number as the warning code.
HARDWARE REFERENCE MANUAL
Control power on
<Node address display>
<Normal display (When the Initial State Indication (Pn700) is set to 0.)>
Main power is ON
Main power is OFF and the network
and the network
communication is not established.
communication
is established.
Servo-ON
Servo-OFF
Alarm occurs
Alarm cleared
*1
<Alarm display>
The alarm code in a decimal number flashes.
(E.g. overload)
*1. When the Safety input error (Err30.0) occurs, the alarm code is not shown. Instead, "St" flashes.
fig. 41
Fully unlit
Fully lit (for approx. 0.6 s)
[nA] (Node Address) (for approx. 0.6 s)
Rotary switch setting (This example is the case
when the MSD is set to 0 and the LSD is to 3.)
(Displays for the period set on Address Display
Time Setting at Power-On (Pn701).)
[− −]
[− −]+Right dot lights
[00]+Right dot lights
Warning occurs
Warning resolved
<Warning display>
The warning code hex and the normal
indication show alternatively. (E.g. overload)
Warning code
Normal indication
(for 2 s)
(for approx 4 s)
94