Sensor Unit (Common For All Models) - Optex Virtual Loop Installation Instructions Manual

Vehicle detection sensor for gate
Table of Contents

Advertisement

3-3

Sensor unit (Common for all models)

Terminal block
●Operation indicator
Operation mode
Standard operation mode
Smartphone App connected mode
*1︓Press and hold the reset button for 5 to 10 seconds for the factory reset.
*2︓The operation indicator flashing blue for 30 seconds, it will automatically return to the normal operation mode.
*3︓Calibration has not been performed.
*4︓After blinking for 10 seconds, it returns to the status of Normal operation. Calibration is completed.
*3, 4 : Refer P18 "7-3 Calibration" to fix this issue.
*5 : The operation indicator is always On, even if "Indicator" in App is set to "Off".
●Terminal block
Connect the power cable to the "Power supply" terminals, and relay output cables to the output terminals.
Pay careful attention to output differences, and select output 1 or 2 according to the application.
Applicable wire
Solid wire: 0.5-1.2mm(0.02-0.05in) (AWG 30-16)
Stranded wire: 0.3-2.0sq (AWG 22-14)
Sensor reset
NOTE
All settings including password and calibration value can be returned to the factory default.
If you relocate the sensor, please reset the sensor. Press and hold the factory reset button for 5
to 10 seconds to return for the factory reset. When the reset is completed, the operation
indicator lights up in blue for 2 seconds. It is also possible to reset it by selecting the menu item
"Reset to factory default settings" in the app.
Sensor unit
Operation status
Standard operation
Start up
Factory reset
Standard operation
Area check
Calibration
Terminal block 1
Factory reset button
Terminal block 2
Operation indicator can be selected to On / Off.
(Refer P30 8-4-1 "Operation Indicator" )
Status
Standby
Standby Enviromental notification
Pre-detection
Detection
Calibration uncompleted
Start up
Complete
Standby
Standby Enviromental notification
Pre-detection
Detection
Calibration uncompleted
Standby
Pre-detection
Detection
In process
Unstable error
High reflection error
High reflection
N.O. COM
N.C.
Output 1
Power
Output 2
Input
N.C. COM
N.O.
IN
GND
-5-
Operation indicator
Solid Green
Solid Purple
Solid Yellow
Solid Red
Solid Blue
Solid Blue (two sec)
Blinking Blue(Fast)
Blinking Green(Slow)
Blinking Purple(Slow)
Blinking Yellow(Slow)
Blinking Red(Slow)
Blinking Blue(Slow)
Blinking Green
*2
Blinking Yellow
Blinking Red
Blinking Blue & Green
Blinking Red & Yellow(Fast)
Blinking Red & Blue(Fast)
Blinking Purple
*4
Non-voltage solid state relay output
30VDC 0.3A or less
(resistance load)
Power supply 12 to 24VAC/DC
+
︓Terminal block1
︓Terminal block2
Contact input
Non-voltage mechanical relay output
30VDC 1A or less
(resistance load)
*1
*3
*3

Advertisement