Download Print this page
Optex VIRTUAL LOOP OVS 01GT Manual

Optex VIRTUAL LOOP OVS 01GT Manual

Hide thumbs Also See for VIRTUAL LOOP OVS 01GT:

Advertisement

Quick Links

OVS-01GT
Product set up guide
Version. 12MAR2020

Advertisement

loading

Summary of Contents for Optex VIRTUAL LOOP OVS 01GT

  • Page 1 OVS-01GT Product set up guide Version. 12MAR2020...
  • Page 2: Product Package

    OVS 01GT Setup Guide Product Package What’s inside • OVS-01GT(E) • Quick reference guide • Installation Instructions • 12mm x 3mmφ screw (4 sets) Options • OVS-TB01: 45 degree mounting bracket...
  • Page 3 OVS 01GT Setup Guide...
  • Page 4 OVS 01GT Setup Guide 3 points to remember - Mounting Height - Angle - Calibration...
  • Page 5: Mounting Height

    OVS 01GT Setup Guide Mounting Height If “activation mode” is used for a sloped approach, the height may need to be adjusted. 0.5 m...
  • Page 6 Pick an angle OVS 01GT Setup Guide: degree degree Activation mode Protection mode Set to “ ” Set to “ ” TIP2: Leave more than 30cm TIP3: distance from bars. Use OVS-01TB 45 degree bracket TIP1: 90 degree can also be used as more stable activation trigger.
  • Page 7 OVS 01GT Setup Guide Calibration & Walk test (Area check) Stand off to a side. Press and hold until LED flash in blue...
  • Page 8 OVS 01GT Setup Guide: Note about “Area Check” human cancellation Yes, OVS-01GT has “ ”! However, you can still check its detection Walking around area by “ ” Green Flash: You are outside of a Microwave(Mw) trigger zone. Yellow Flash: You are inside of a Mw trigger zone.
  • Page 9: Setup Flow

    OVS 01GT Setup Guide Set up flow Recommended Initial setting (Default setting) 1. Fix position: height and angle 2. Run cables and power the device up 3. Set detection range and run calibration - See if the device functions on the default setting. 4.
  • Page 10 OVS 01GT Setup Guide Examples...
  • Page 11 Interface Modification NEW Interface (Not final: subject to change) Q3 2020 New labels to be applied to production in no change There is in performances, features and algorism to the current model.
  • Page 12 OVS 01GT Setup Guide Frequently told answers 1. Unlike Induction loops, OVS-01GT requires sensitivity tuning and calibrations. 2. Slopes and obstacles in the detection range will affect detection performances. 3. Yes, buttons are hard to press, but you will feel a click when pressed on circles. 4.
  • Page 13 Then, the device will go off by a Mute the If no closed connection is made, human presence. Inhibit Normally Open sensitivity of the device will stay at muted. Closed detection (No trigger at all) Copyright (C) 2016 OPTEX CO., LTD. CONFIDENTIAL...
  • Page 14 OVS 01GT Setup Guide For any question or set up guidance, please send inquiry to: tech-support@optex-europe.com Thank you.