Super X13DEG-M User's Manual
Power Management
•
ACPI power management
•
S1, S4, S5 support
•
Power button override mechanism
•
Power-on mode for AC power recovery
•
Wake-on-LAN
•
Power supply monitoring
System Health Monitoring
•
Onboard voltage monitoring for +12 V, +5 V, + 5V standby, +3.3 V, +3.3 V standby, and Vcore
•
Temperature monitoring for CPU, VRM, PCH, system, memory, PLX, and AOC LAN
•
7+1 CPU switch phase voltage regulator
•
CPU thermal trip support
•
Platform Environment Control Interface (PECI)
Fan Control
•
Fan status monitoring via BMC connections
•
Single cooling zone
•
Low-noise fan speed control
•
Four 6-pin fan headers
System Management
•
Server platform service
Firmware Integrity/System Security
•
TPM (Trusted Platform Module) support
•
RoT (Root of Trust) support to protect firmware security by detecting critical data corruption, and restoring platform integrity
LED Indicators
•
Power LED
•
M.2 LEDs
•
BMC/CPLD firmware LED
Dimensions
•
Proprietary form factor in 14.95" (W) X 17.00" (L) (379.73 mm x 431.8 mm)
Note 1: The CPU maximum thermal design power (TDP) is subject to chassis and
heatsink cooling restrictions. For proper thermal management, please check the chas-
sis and heatsink specifications.
Note 2: For BMC configuration instructions, please refer to the Embedded BMC Con-
figuration User's Guide available at https://www.supermicro.com/support/manuals/.
16