This feature displays the PCie generic and NVMe drive informatiion of the NVMe device(s).
Intel(R) VROC SATA Controller
Note 1: This section is based on your system features and related device(s) installed.
Note 2: This section is available after you configure Advanced -> PCH
figuration -> "SATA Mode Selection" to RAID, save the settings and reboot the system
to apply the changes.
The following information is displayed.
Intel VROC SATA driver version
Create RAID Volume
Name:
This feature allows you to enter the unique name of RAID volume.
RAID Level:
This feature allows you to select the RAID level. The options are RAID0(Stripe),
RAID1(Mirror), RAID5(Parity), and RAID10(RAID0+1).
Select Disks:
Select the desired RAID disks one by one by setting them to X. The options are (not
selected) and X (selected).
Strip Size:
Use this feature to select the RAID strip size. The options are 4KB, 8KB, 16KB, 32KB,
64KB, and 128KB. The available options are based on the setting of "RAID Level:" above.
Capacity (GB):
This feature allows you to enter the desired RAID capacity (in GB).
RWH Policy (Available for RAID5 Only)
Select a desired RAID Write Hole (RWH) policy when RWH occurs. If no disk has been
set as a journaling drive, the options are Distributed PPL and Disable. If any disk has been
set as a journaling drive, the options are Distributed PPL, Journaling Drive, and Disable.
For details on creating a journaling drive, refer to the Non-RAID Physical Disks section.
Note 1: A RWH occurs when a drive failure and power failure happen simultaneously or
close to each other during the write. The events of a drive failure and power failure are
141