Rear I/O Connectors/Ports - Supermicro X13DET-B User Manual

Table of Contents

Advertisement

2.5 Rear I/O Connectors/Ports

UID/BMC Reset Switch (JUIDB1) and UID_LED/BMC LED Indicator
A UID LED/BMC Reset switch (JUIDB1) is located on the rear I/O panel of the motherboard.
This switch has dual functions. It can function as a unit identifier (UID) to identify a system
unit that is in need of service, and it can also be used for BMC reset.
To achieve these purposes, JUIDB1 works in conjunction with the UID_LED1/LEDBMC LED
indicator located on the rear I/O panel for both UID and BMC Reset support.
When functioning as a UID LED switch, JUIDB1 will turn on/off the blue signals of the UID_
LED1/LEDBMC LED indicator when the user presses the switch on/off.
When functioning as a BMC reset switch, JUIDB1 will reset the BMC settings to the
manufacturer defaults when the user presses and holds the switch for 12 seconds, and it will
trigger a cold reboot when the user presses and holds it for 6 seconds.
Refer to the BMC User's Guide posted on our website at http://www.supermicro.com for more
information.
When Used as a UID LED Switch
UID_LED1/LEDBM acting as a rear UID LED
indicator (Blue)
UID_LED1/LEDBMC: Blue: Unit in need of
services is identified
Press the switch (JUIDB1) on and off to turn
the blue signals of UID_LED1/LEDBMC LED
indicator on and off
2
1
JUIDB1
UID_LED1
LE6
JVGA1
VGA
JPME1
UID
USB0/1
IPMI_LAN
(3.0)
SLOT1
BMC
BIOS
SATA 8~11
JTPM1
1
P1 AIOM PCIe 5.0 X16
JAIOM
BT1
LE1
SATA1
JPME2
BIOS
PCH
LICENSE
BAR CODE
IPMI CODE
SATA 0~7
X13DET-B
REV:1.01
JBT1
CPU1
SXB4
SXB3
SXB1
JPWR4
JPWR3
JPWR2
JPWR1
CPU2
UID/BMC Reset Switch (JUIDB1)
Features & Settings
When Used as a BMC Reset Switch
UID_LED1/LEDBMC acting as a BMC Reset LED indicator (Green)
UID_LED1/LEDBMC: Green Blinking: BMC (BMC Heartbeat) Normal
BMC Reset: Press
& hold the JUIDB1
switch for 6 seconds
BMC Reset: Press
& hold the JUIDB1
switch for 12 seconds
UID/BMC Reset Switch (JUIDB1)
Pin Definitions
Pin#
Definition
1
Ground
2
Ground
3
Button In
4
Button In
SXB5
UID_LED1/LEDBMC: Solid green during reboot
Triggering a cold reboot; the UID_LED1/LEDBMC
indicator: Solid green on during cold reboot
UID_LED1/LEDBMC: Solid green during BMC reset
BMC: Reset to the manufacturer default; UID_LED1/
LEDBMC: Solid green on during BMC Reset
1. UID LED/BMC Reset Switch
2. UID_LED1/LEDBMC indicator
59
Chapter 2: Installation

Advertisement

Table of Contents
loading

Table of Contents