WARNING!
Before performing any work on the electric
power tool, pull out the mains plug.
Before switching on the power tool
Unpack the electric power tool and check
that no parts are missing or damaged.
Connection to the isolating
transformer – power tools with
contour plug
WARNING!
In accordance with VDE 0100 hand-
operated machines used for wet working
must be operated via a suitable isolating
transformer in accordance with EN 61558.
CAUTION!
Voltage specifications on the rating plate of
the electric power tool must correspond with
the output voltage of the isolating
transformer used.
The electric power tool features a contour
plug in accordance with IEC 60309-2 with
an earth contact in the 12 o'clock position
which allows the connection to an isolating
transformer with corresponding socket.
The FLEX isolating transformer TT 2602/
TT 2000 complies with the stated
regulations.
WARNING!
Only have the replacement of the contour
plug performed on the wet stone polisher by
correspondingly qualified specialists or
customer service.
Connection to the power supply –
power tools with PRCD switch
WARNING!
These machines may be operated with the
supplied PRCD switch only.
Before using the machine, always check the
PRCD switch.
Always check the machine before use:
1. Insert the mains plug into the socket.
2. Press "RESET" button.
The red indicator light must come on.
3. Press "TEST" button.
The PRCD switch must switch off and
the indicator light go out.
4. When the "RESET" button is pressed
again, it must be possible to switch on
the machine.
WARNING!
If the PRCD switch repeatedly switches off
when the machine is switched on or if the
PRCD switch does not trip, immediately
disconnect the machine from the power
supply.
Do not continue using the machine. Have
the PRCD switch replaced by appropriately
qualified technicians or customer service
only.