Connecting the water
WARNING!
Keep water away from the electric power
tool and from people within the operating
range. Do not switch on power tools which
have not been connected correctly to the
water supply. Regularly check that seals,
shut-off valve and connectors function
correctly.
NOTE
If there is no connection to the water supply
mains, it is recommended to use the mobile
water pressure tank WD 10 (capacity 10 litres,
4 m pressure hose, order no. 251.622).
Attach ½" water hose to standard self-
locking quick coupling.
Do not open shut-off valve until at the
place of use and the grinding tool is
rotating.
When removing the hose, ensure that no
water runs into the machine.
20
LE 12-3 100 WET/L 12-3 100 WET
Attaching or changing the grinding
tool
WARNING!
Before performing any work on the electric
power tool, pull out the mains plug.
NOTE
The M14 thread must have a depth of at
least 20 mm.
Press spindle lock (1.).
Unscrew tool holder (2.).
Press spindle lock again (3.).
Screw on new tool holder (4.).