The Top Safety Line - Handicare 1100 Quick Reference Manual

Hide thumbs Also See for 1100:
Table of Contents

Advertisement

Handicare 1100
8
|

The top safety line

The next components are part of the top safety line:
The top footrest switch
The top cover switch
Code "4"
F A U L T
Display
Action
Top safety edge activated
F A U L T
When pushing the toggle in upwards direction, the lift don't move. The powered swivel motor
functions.
Symptoms
Lift moves up
Lift moves down
Powered swivel
Powered footrest
Cause right handed lift
The top footrest switch (S3) is defect/activated
The top cover switch (S5) is defect/activated
Wire break between: A15-2 (4,3 V), A14-4, S3, A14-3, A15-1, A1-6
Cause left handed lift
The top footrest switch (S4) is defect/activated
The top cover switch (S6) is defect/activated
Wire break between: A15-4 (4,3 V), A14-6, S4, A14-5, A15-3, A1-5
When the elevator is moving and a direction switch or the seat position switch is pressed, the
display will show a "6" or "4".
When the joystick/remote control is pressed again, the display shows "6". or '4'.
In the case of an electric swivel seat, the seat tries to rotate into the driving position.
20
D
Right
Connection
A1-5
A1-6
Left
Connection
A1-5
A1-6
Function
no
yes
yes
yes
Standard
Faulty
4,3 V
4,3 V
4,3 V
0 V
Standard
Faulty
4,3 V
0 V
4,3 V
4,3 V

Advertisement