Handicare 1100 Quick Reference Manual page 14

Hide thumbs Also See for 1100:
Table of Contents

Advertisement

Handicare 1100
General safety line
The emergency stop LED
If the emergency stop is pressed, the general safety line will be interrupted. The LED in the
emergency stop will light up to attract the user.
The power from the LED comes from the power on the toggle line.
The Led in the emergency stop is not functioning
If the led in the emergency stop does not light up when the emergency stop is activated:
The LED is defect
Wire break between A1-8, A8-8, A11-2, S13
Code "0" The lift is not moving, the powered swivel is functioning,
the powered footrest don't function
ion
Display
The pink wire from A1-4 to A9-1 makes sure the powered footrest is functioning when the
chair position switch is interrupted.
Symptoms
Lift moves up
Lift moves down
Powered swivel
Powered footrest
14
Connection
Action
A1-4
A1-5
A1-6
A1-10
Function
Cause
Wire break between A9-1, A8-4, and A1-4
yes
yes
yes
no
Standard
Faulty
4,3 V
10,7 V
4,3 V
0 V
4,3 V
0 V
4,3 V
0 V