ISS 8, SECTION 573-115-700TC
3. 41
Print Suppression and Offline Stunt
Shift
Control Mechanism
(A) SUPPRESSION CODE BAR POSITION
REQUIREMENT
NOTCHES IN SUPPRESSION CODE BAR SHOULD ALIGN WITH NOTCHES IN OTHER
CODE BARS. VIEW FROM REAR OF UNIT ABOVE STUNT BOX. GAUGE BY EYE.
TO CHECK
ENERGIZE THE PRINT SUPPRESSION MAGNET AND PLACE ALL CODE BARS IN
SPACING POSITION.
TO ADJUST
OPERATE MAGNET ARMATURE MANUALLY OR ELECTRICALLY. PLACE ALL CODE BARS
IN SPACING POSITION. PIVOT THE ARMATURE EXTENSION IN ITS ELONGATED
MOUNTING HOLE WITH THE MOUNTING SCREWS LOOSENED. TIGHTEN SCREWS.
MOUNTING
BRACKET~
iii(£' - - - -
·YOKE----..
PRINT SUPPRESSION
MAGNET
-!
t..-
TOP VIEW LEFT SIDE
(E)
PRINT SUPPRESSION MAGNET ARMATURE RETURN SPRING
REQUIREMENT
MIN.
7
OZS.
MAX.
JO~l/2
OZS.
TO START MAGNET ARMATURE MOVlNG TOWARD CORE
TO CHECK
PRINT SUPPRESSION MAGNET UNOPERATED
SUPPRESSION
CODE BAR
ARMATURE EXTENSION
(B) TYPE BOX CLUTCH TRIP LEVER
SEE PAR. 2.22 AND REFINE
REQUIREMENT TO
MIN. 0.040 INCH
MAX.
0.055
INCH
{C) TYPE BOX CLll[CH SUPPRESSION ARM
SEE PAR.
3.14'
{D)
BLOCKING BAIL
SEE PAR.
3.14
NOTE: KEEP POLE FACE FREE
OF OIL AND GREASE.