Venting; Overview - Valor Portrait 530INI Installation Manual

Direct vent insert gas fireplace
Hide thumbs Also See for Portrait 530INI:
Table of Contents

Advertisement

Venting

Typical Vent Installation
See the Approved Venting Components list on page 45 of
this manual.
Vent Location
The vent terminal must be located through the roof.
This direct vent appliance is designed to operate when
an undisturbed airflow hits the outside vent terminal
from any direction.
Check local codes for allowable vertical vent
termination.
Venting Table
Maximum
40 ft (measured to bottom of termination)
vertical height
Minimum
10 ft (measured to bottom of termination)
vertical height
Maximum
4 ft (measured center to center of pipe)
horizontal run
Maximum offset
45˚ (sweeping bend to allow for obstructions)
angle
Venting Notes
Where possible, avoid splicing flex pipes. If splices are
required, use a approved connector and seal joints with
RTV high temp sealant.
Four feet horizontal is permissible to allow for routing
around masonry projections. Do not bend flex pipe
over a 45 degrees radius.
1. Co-linear venting may be converted to solid 4" x
6-5/8" co-axial venting at the top of the existing sol-
id-fuel burning chimney as necessary where the ex-
isting chimney has deteriorated and been removed.
The conversion must be done using approved com-
ponents (see page 45) and proper vent clearances
to combustibles must be maintained.
2. Flex liners may only be installed into solid-fuel burn-
ing fi replaces and chimney systems (no combustible
construction).
3. The appliance must not be connected to a chimney
fl ue serving a separate solid-fuel burning appliance.
Note
This appliance may also be vented using the following
optional methods (see installation instructions
packaged with optional kits):
• 720SWK—Co-linear sidewall kit
Terminal Cap (co-linear)
Flashing
2 x 3" flex liners
—see Venting Table
for length allowed
3" Liners
3" min.
Bend
Radius
Co-linear applications
Terminal Cap (co-axial)
Terminal Adapter
and Flashing
supplied with
590FVK2
5 x 3" flex liners supplied
with 590FVK2 kit—
see Venting Table for
length allowed
5 x 3" Liners
5" min.
Bend
Radius
Co-axial applications

Overview

13