Graco G3-G-24MX-2L0L00-10CV00R0 Instructions Manual page 78

Max automatic lubrication pump
Hide thumbs Also See for G3-G-24MX-2L0L00-10CV00R0:
Table of Contents

Advertisement

Troubleshooting
Problem
Unit indicates a cycle or pressure
alarm before the lubrication cycle
could complete
In an Injector System without sensor
feedback, unit does not vent prop-
erly
Display acts erratically
USB Error 00
USB Error 07
USB Error 11
USB Error 12
USB Error 13
78
Cause
The ON Time was not entered cor-
rectly
Vent valve time needs to be config-
ured
Faulty cycle/pressure wiring connec-
tion to unit
Flash drive was removed during
operation
Flash drive unable to mount (initial-
ize)
Pump program setting file not found Verify that the pump program setting
Pump program settings directory not
found.
Bad pump program settings file
Settings file is from different firm-
ware version
Solution
Refer to programming ON Time,
pages 35 and 58.
Refer to Advanced Programming to
set ON Time, page 49.
Unplug cycle/pressure cables from
G3. Plug cables in one at a time to
identify the faulty connection.
Keep the flash drive plugged in until
the unit has completed the opera-
tion.
Unplug the flash drive and
re-install.
Cycle power and re-install the
flash drive.
Retry using a different flash
drive.
Verify format is FAT32 file sys-
tem. If not, may need to reformat
flash drive or find a different
drive that has this file system.
If any of the above do not rectify the
error, contact Graco Customer Ser-
vice.
folder structure and file are stored
correctly on the flash drive. See Stor-
ing Pump Program Settings to the
Flash Drive, page 41 for instructions.
Verify that the pump program setting
folder structure and file are stored
correctly on the flash drive. See Stor-
ing Pump Program Settings to the
Flash Drive, page 41 for instructions.
The pump programs settings file is
corrupt. Restore file to the flash
drive. See Storing Pump Program
Settings to the Flash Drive, page 41
for instructions.
Program pump manually or recreate
settings file from a pump that has the
same firmware version. See Storing
Pump Program Settings to the Flash
Drive, page 41 for instructions.
332305R

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3-g-24mx-2lfl00-10cv00r0G3-g-acmx-2l0l00-1d0v0000G3-g-acmx-2lfl00-1d0v0000G3-g-12mx-2l0l00-1dmva2r3G3-g-24mx-2l0l00-1dmva2r3G3-g-24mx-2lfl00-1dmva2r3 ... Show all

Table of Contents